Delta HEX150PC Instruction Manual

Heat exchanger

Advertisement

Quick Links

HEX150PC Heat Exchanger
Instruction Manual
USA
46101 Fremont Blvd, Fremont, CA 94538, U.S.A.
TEL : 1-510-668-5100
FAX : 1-510-668-0680
Cabinet-Thermal-Solutions@deltaww.com
Taiwan
Delta Electronics, Inc.
252, Shang Ying Road, Kuei San District
TEL : 886-(0)3-3591968
Taoyuan City 33341, Taiwan, R. O. C.
FAX : 886-(0)3-3591991

Advertisement

Table of Contents
loading

Summary of Contents for Delta HEX150PC

  • Page 1 HEX150PC Heat Exchanger Instruction Manual 46101 Fremont Blvd, Fremont, CA 94538, U.S.A. TEL : 1-510-668-5100 FAX : 1-510-668-0680 Cabinet-Thermal-Solutions@deltaww.com Taiwan Delta Electronics, Inc. 252, Shang Ying Road, Kuei San District TEL : 886-(0)3-3591968 Taoyuan City 33341, Taiwan, R. O. C.
  • Page 2: Table Of Contents

    Table of contents 1. Version ......................1 2. Description ....................1 2-1. General ....................1 2-2. Specification ..................1 2-3. Environmental condition ..............2 3. Installation ....................2 3-1. Outline drawing .................. 2 3-2. Mounting panel cutout and waterproof foam sticking ....3 4.
  • Page 3: Version

    2016/6/10 2. Description 2-1 . General Delta Heat Exchanger (HEX) is designed for direct air to air heat exchange to remove heat from the cabinet. The internal and the external air circulation loops of the HEX are separated to prevent the introduction of dust, humidity and dirt. The fan on the external air loop conforms to IP55 protection rating.
  • Page 4: Environmental Condition

    HEX150PC Heat Exchanger Instruction Manual 2-3 . Environmental condition Description Specification Operating -10° C ~ +65° C (-14° F ~ 149° F) temperature Storage -40° C ~ +70° C (-40° F ~ 158° F) temperature External air circuit: 0 ~ 100% RH...
  • Page 5: Mounting Panel Cutout And Waterproof Foam Sticking

    HEX150PC Heat Exchanger Instruction Manual 3-2 . Mounting panel cutout and waterproof foam sticking : : 4. Electrical specification 4-1. Connection and LED indicator (on HEX panel) Power Connection on panel plate : CVILUX 3W3CS0000100000 mate with : CVILUX 3W3CP0000100000...
  • Page 6 HEX150PC Heat Exchanger Instruction Manual User can follow dry contact definition that is Normal Close (N.C.) to detect abnormal status from pin 10 & pin 11 Definition N. C Connection Pin 10 & Pin 11 Control board, NTC and fan are in...
  • Page 7: Standalone Control Mode

    HEX150PC Heat Exchanger Instruction Manual NTC temperature sensor User can switch inner sensor (on control panel) or external sensor (COMM port Pin7 & Pin8 ) via J13 connector on controller as shown below to change sensor location . 4-2. Standalone control mode HEX can detect ambient temperature to control cooling capacity .
  • Page 8: Mechanical Feature

    HEX150PC Heat Exchanger Instruction Manual 5. Mechanical feature 5-1 . Thermal path and Airflow baffle With forced convection using the axial fan, warm air generated by the equipment will be blown into the internal return opening and pass though the HEX, then flow out from internal supply opening. The air supply of the cold air will be used to cool down the system;...
  • Page 9: Maintenance And Replacement

    HEX150PC Heat Exchanger Instruction Manual 6. Maintenance and Replacement Be sure to SHUT DOWN the power before proceeding with any maintenance or component replacement . 6-1. Maintenance Monthly Use brush and low pressure air to remove dust or any debris on both internal/external air inlet and air outlet opening .
  • Page 10: Replacement

    Refer to Section 4-1 for checking abnormal part is internal fan , external fan or controller for abnormalities . In cases of parts abnormality , Delta will follow the reading and submit spare part(s) below for replacement . Internal fan P/N : AFB1548EH-BJ51...
  • Page 11: Safety

    HEX150PC Heat Exchanger Instruction Manual 8. Safety 9. Accessory 9-1. Power cable 9-2. Function cable 10. General Safety and Warnings * Some electronic parts have a high operating temperature . Use caution at all times. * Incorrect installation may cause damage and/or injury.