1 Scope of delivery

• SAUTER TVL
• A hook

2 Technical description

2.1 Technical data test bench
maximum force
Measurement direction
Spindle stroke per
revolution
Mounting height of upper
hook from base plate
Thread hook
Spindle height from base
plate
Thread of the encoder
mounting plate
Workspace
Weight
2.2
Technical data length measuring unit LA (without serial interface)
Scale length
Readability
On/0
mm/in

3 Maintenance

To avoid rust, the test stand should be cleaned with a soft cloth after each use.
Under no circumstances should aggressive cleaning agents be used.
TVL_TVL-XL-BA-e-2121
TVL
vertical and horizontal
Approx. 470mm
4x M3 (included in delivery)
Approx. 200mm
8kg
TVL
Control buttons
• Zeroing the display of the LA
Change of units between millimeters and inches
Manual length preselection, upwards
Manual length selection, downwards
TVL-XL
500N
3mm
Approx. 720
M6
230mm
Approx. 450mm
15kg
TVL-XL
200mm
0,01mm
• Switch on
3

Advertisement

loading

This manual is also suitable for:

Tvl-xl