Providing AC Power

Connecting the Aqua-Hot to AC Power

The following section will detail how to connect the Aqua-
Hot to the vehicle's AC electric system. Connect the 3-pin Molex
connector to the coach-side AC electric system in order to utilize
the Aqua-Hot's AC heating element.
The Aqua-Hot utilizes Molex 19403 and 19045 series con-
nectors for the AC electrical circuit. These are self-contained
connectors which can be readily purchased from your choice
of electronics supplier. Listed below are three different mating
connections.
Self-Contained Power Connector - 2 Circuit for Solid Wire
Size
Part Number
Housing Color
12-14AWG
19045-1000
White
(2.00mm
)
2
Self-Contained Power Connector - 2 Circuit for Stranded Wire
14-16AWG
19403-1011
Blue
(2.00mm
)
2
12AWG
19403-1010
Yellow
(2.00mm
2
)
Installation must be performed by a qualified profession-
al according to current national regulations. Reference
A119.2/NFPA 501C Standard on Recreational Vehicles
1993 Edition.
The boiler must be connected to a 120V AC supply perma-
nently and be protected with a 20A breaker (minimum). The
120V AC must be separate from 12V DC.
It must be possible to disconnect the power to the boiler,
either an easily accessible plug or a circuit breaker.
Please refer to the schematic on page 56.
Molex 19045-1000
Figure 55
p. 26
©Aqua-Hot®
125-GN1 Installation Manual REV 220427
AC Electric Connection
Molex 19403-1010
Molex 19403-1011
Figure 56
Cozy heat exchangers can be mounted in one of two
configurations: either flat on the ground, or vertically. Reference
Figure 58.
Supply ventilation cross-sectional area of at least 29in
2
(74cm
) must be supplied to each heat exchanger.
Do not supply heat exchangers air which is drawn from the
bay areas.
Return air should be drawn from the same room the heat
exchanger is heating.
The anti-freeze and water heating solution must flow in
through the bottom of the heat exchanger, and out the top
(reference Figure 69).
The Aqua-Hot 125GN is designed to work with up to 3
thermostatic heating zones.
Figure 54
Figure 57
Heat Exchanger Installation Requirements
Vertical Orientation
2
©Aqua-Hot®
125-GN1 Installation Manual REV 220427

Installing Heat Exchangers

Horizontal Orientation
Figure 58
Figure 59
p. 27

Advertisement