aqua-Hot Hydronic Heating system

Figure 1
Diesel-Burner, Heat Input (Firing Rate) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56,000 BTU/hr.
Diesel-Burner, Fuel Consumption (Continuous Operation) . . . . . . . . . . . . . . . . 0.40 gal/hr.
Heater, Voltage/Maximum Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . 12 Volt-DC/60 watts
Electric Heating Element specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (2) 120 Volt-AC/2000 watts
Zone Heat Circulation Pump specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . (3) 12 Volt-DC/21 watts each
Number of Heating Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . maximum of 5, plus Engine Preheat
Domestic Water Heating Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . continuous/on-demand
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.5"H x 18.5"W x 36.75"L
Dry Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approximately 186 lbs.
Wet Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approximately 303 lbs.
— Page 2 —
© 2008 Aqua-Hot
®
600-D Hydronic Heating System Installation Manual