Mounting the Aqua-Hot LCD

Mounting the Aqua-Hot LCD
This following section will explain in detail how to mount the Aqua-Hot LCD on the interior of the RV.
Mounting Considerations:
Purchase the necessary RV-C connection parts according
to the table below.
Manufacturer
Part Number
Common Name
37104-A165-
3M
Network Port
00E-MB
RV-C Communication
General Cable
E2104S.41.02
Cable
Route the 15' RV-C cable from the intended mounting
position of the LCD to the Aqua-Hot Controller.
The LCD screen is powered via the RV-C cable which
connects directly to the Aqua-Hot Controller, or via an on-
board RV-C network.
"DATA ONLY" RV-C cable configurations are not compatible
with the LCD screen.
The screen requires at least ¾" (1.9cm) of backside
clearance to allow room for cables and connections.
Reference Page 38 for more information on the RV-C
Network Connectivity.
Mounting Procedure
1. Select a location within the RV.
2. Cut a 2.50" x 3.64" hole in the RV wall.
3. Route the corners of this cutout with a .35" diameter bit.
4. Using four countersunk #6 screws, secure the LCD bracket
into place over the cutout just made.
5. Connect the RV-C cable to the back of the LCD screen.
Reference Figure 76.
6. Snap the LCD screen into the mounting bracket.
RV-C Connection
Figure 76
p. 34
©Aqua-Hot®
125-GN1 Installation Manual REV 220427
3.5" LCD Diagnostic Screen
Figure 77
NOTE: Please note that the LCD Screen mounting bracket
may only be mounted in this configuration as shown below.
The screen will not fit in properly any other way.
2.843"
2.455"
Ø 0.150"
(X4)
2.500"
3.655"
4.047"
3.640"
Figure 78
Operating the LCD & Aqua-Hot
This section will outline the basic operating instructions for the Aqua-Hot LCD Screen.
Climate Pages:
The climate pages are for all intents and purposes the
"Home" of the LCD screen. From here, the end-user will select
their interior temperature set-points, activate or deactivate the
gas burner and/or the electric element.
1A
1
2
3
4
5
Zone Control (1):
Precise zone control display will differ depending on the type
of zone thermostats/thermistors used within the RV.
Section 1A demonstrates the appearance of the zone
control section when ON/OFF thermostats are used within the
RV. In this use-case, these buttons serve only as ON/OFF toggle
switches.
A
B
C
Tapping on one of the zones shown above will display a new
screen where the interior temperature can be set.
Section A:
This section shows the current zone
temperature (shown as 71°F in the example
above) as well as a button to turn the zone
on or off. (Setting specific temperatures can
only be done if thermistors are installed.
Thermostats would only show ON/OFF.)
©Aqua-Hot®
125-GN1 Installation Manual REV 220427
Mounting the Aqua-Hot LCD
Operating the LCD
If the zone temperature is set, but this item
is not set to ON, the zone heat exchanger will
not activate.
Section B:
These arrows are used to increase or decrease
the desired set-point temperature of the zone
thermistor.
Section C:
After the desired temperature set-point has
been selected tap "SET" on the LCD to set
that temperature. The Aqua-Hot will now work
to maintain this interior temperature, and the
screen will return home.
External Gas Burner Activation (2):
The external gas burner of the Aqua-Hot can be activated by
tapping on the "burner" item on-screen. The gas burner has two
modes: ON and OFF.
ON:
While set to ON, the Aqua-Hot gas burner will
work to maintain a tank temperature of 180°
F, with a minimum tank temperature of 160° F.
OFF:
While off, the gas burner will not serve to
provide any heat to the boiler of the Aqua-Hot
whatsoever.
Electrical Element Activation (3):
Similar to the external gas burner, tapping this button
will signal to the controller to activate the AC electric relay,
energizing the 1500W electric element within the Aqua-Hot.
The electric heating element has two modes: ON and OFF.
ON:
While set to ON, the electric element will work
to maintain a tank temperature of 180° F,
with a minimum tank temperature of 160° F.
OFF:
While off, the element will not serve to
provide any heat to the boiler of the Aqua-Hot
whatsoever.