PRECAUTIONS
A_ Perform an appliance reset cycle.
B_ Disconnect the appliance from the electricity supply
C_ Remove the detergent intake nozzles from the cans, and remove the cans from the appliance in
the case of 4190 appliances.
D_ Disconnect the water outlet and inlet connections from the drain and supply systems.
4
PROCEDURE
To simplify operations, the appliance should be placed well above the ground and with the rear projecting slightly
from the supporting surface for easier insertion of the base tray.
PROCEDURE
1. Turn the appliance onto its side, remove the
front plinth and the drip guard underneath it
and take off the feet.
2. Remove the steel bottom guard and find the
wiring for connection to the float switch
assembly. (The connector to be used is secured
with a tie near the bottom of the appliance).
902897-903079
ILLUSTRATION
3
Figure 1
Figure 2