Dimensions d'encadrement minimales - Configuration de l'évent arrière
HINT: place the fireplace so the center
line is at least 5" (127mm) from both
vertical framing members at the rear (this
allows the vent to pass through the
framing without modfications)
Route the
electrical line to
a position to the
left rear of the
fireplace.
Minimum enclosure height = 38-1/2" (978mm)
Travis Industries
Installation
(for qualified installers only)
38-1/2"
978mm
41-1/4"
1048mm
Included Firestop (required)
Part # 93006094
Vent Clearances 8" (203mm) dia. Vent:
1" (25mm) to the sides, 1" (25mm)
below, and 3" (76mm) above the vent to
combustibles.
38"
965mm
25-3/4"
654mm
20-3/4"
528mm
4161122
Center of Rear Vent
30-3/4"
781mm
13
100-01387