Appendix:

Appendix 1: Reference Sheet of Celsius and Fahrenheit

Conversion formula for Fahrenheit degree and Celsius degree: Tf=Tcx1.8+32
Set temperature
Fahrenheit
display
Fahrenheit
temperature
(℉)
61
62/63
64/65
66/67
68
Ambient temperature
Fahrenheit
display
Fahrenheit
temperature
(℉)
32/33
34/35
36
37/38
39/40
41/42
43/44
45
46/47
48/49
50/51
52/53
54

Appendix 2: Configuration of Connection Pipe

1.Standard length of connection pipe(More details please refer to the specifications)
2.Min length of connection pipeFor the unit with standard connection pipe of 5m, there is no limitation for themin length of
connection pipe. For the unit with standard connection pipe of 7.5m and 8m, the min length of connection pipe is 3m.
3.Max length of connection pipe(More details please refer to the specifications)
4.The additional refrigerant oil and refrigerant charging required after prolonging connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for
each additional 5m of connection pipe.
● The calculation method of additional refrigerant charging amount (on the basis of liquid pipe):
● Basing on the length of standard pipe, add refrigerant according to the requirement as shown in the table. The additional
refrigerant charging amount per meter is different according to the diameter of liquid pipe. See Sheet 2.
● Additional refrigerant charging amount = prolonged length of liquid pipe X additional refrigerant charging amount per meter
Diameter of connection pipe
Liquid pipe
1/4''
1/4'' or 3/8''
1/2''
5/8''
3/4''
7/8''
Note: The additional refrigerant charging amount in Sheet 2 is recommendedvalue, not compulsory.
Installation and Maintenance
Fahrenheit
Celsius (℃)
(℉)
temperature
60.8
16
62.6
17
64.4
18
66.2
19
68
20
Fahrenheit
Celsius ( ℃)
(℉)
temperature
32
0
33.8
1
35.6
2
37.4
3
39.2
4
41
5
42.8
6
44.6
7
46.4
8
48.2
9
50
10
51.8
11
53.6
12
Additional refrigerant charging amount for R32
Gas pipe
3/8'' or 1/2''
5/8'' or 3/4''
3/4'' or 7/8''
1'' or 1 1/4''
/
/
display
Fahrenheit
Celsius (℃)
(℉)
(℉)
69/70
69.8
21
71/72
71.6
22
73/74
73.4
23
75/76
75.2
24
77
77
25
display
Fahrenheit
Celsius(℃)
(℉)
(℉)
55/56
55.4
13
57/58
57.2
14
59/60
59
15
61/62
60.8
16
63
62.6
17
64/65
64.4
18
66/67
66.2
19
68/69
68
20
70/71
69.8
21
72
71.6
22
73/74
73.4
23
75/76
75.2
24
77/78
77
25
Indoor unit throttl
Cooling only,cooling
Cooling only(g / m) Cooling and heating(g / m)
and heating(g / m)
16
40
80
136
200
280
Fahrenheit
display
Fahrenheit
(℉)
temperature
(℉)
78/79
80/81
82/83
84/85
86
Fahrenheit
display
Fahrenheit
(℉)
temperature
(℉)
79/80
81
82/83
84/85
86/87
88/89
90
91/92
93/94
95/96
97/98
99
Outdoor unit throttle
12
16
12
40
24
96
48
96
200
200
280
280
Celsius (℃)
78.8
26
80.6
27
82.4
28
84.2
29
86
30
Celsius (℃)
78.8
26
80.6
27
82.4
28
84.2
29
86
30
87.8
31
89.6
32
91.4
33
93.2
34
95
35
96.8
36
98.6
37
109