350-200-111-02, Issue 2
P
ROVISIONING
All HLU-200 List 1A user options can be set using either the front panel
Mode and Select buttons (in conjunction with the four-character display) or
from the Maintenance Terminal menus through a maintenance terminal
connected to the front-panel RS-232 maintenance port.
Only the DS1 line code (B8ZS or AMI) is sent to the Litespan system
manager, which reads the value and then provisions the Litespan Gate Array.
The HLU-200 line code setting is not available from OMAPS (Paragraph
14.3) and must be provisioned directly from the HLU-200.
U
SING THE
To provision the HLU-200 through the SEL and MODE front-panel buttons:
1
Press the MODE button for approximately two seconds. The message
displayed on the front panel alternates between the first system parameter
and its current setting.
2
Press the SEL button to step through all possible settings (one at a time)
of the parameter being displayed.
3
Press the MODE button to select the desired parameter and move to the
next parameter. After you have configured the last parameter, the
display prompts you to confirm the settings.
4
Do one of the following:
Press the SEL button to install the settings.
Press the MODE button to bypass the settings.
If neither button is pressed in 30 seconds, the settings are bypassed.
The following three user options (Default Settings and Using
the Craft Port on page 8, and System Settings on page 9) must
be set using the maintenance terminal interface: Circuit ID,
Time and Date, DS0 Blocking, and Margin Alarm Threshold.
HLU-200 List 1A
M
ODE AND
October 4, 1999
S
B
ELECT
UTTONS

Provisioning

7