EC Declaration of Conformity Declare that machinery described: AHW,AHW(S) Hot water circulator pump Conform to the following directive: 2014 / 30 / EU Electromagnetic Compatibility Directive 2014 / 35 / EU Low Voltage Directive 2006 / 42 / EU Machinery Directive 2009 /125/ EU Εcodesign requirements for energy-related products...
Page 3
Symbols used in this document Warning • Prior to installa�on, read these installa�on and opera�ng instruc�ons. Installa�on and opera�on must comply with local regula�ons and ac- cepted codes of good prac�ce. • The use of this product requires experience with and knowledge of the product.
General description The AHW(S) circulator is designed for circula�ng water in closed hydron- ic hea�ng systems or potable water systems. Underfloor hea�ng s ystems, single and double-hea�ng systems, Ground source heat systems, Boiler/Solar water hea�ng systems, Hot-water recircula�on systems, Water circula�on for cooling air-condi�oning sys-...
Installation Follow the arrow on the pump casing for direc�on of water flow, it may be installed at ver�cal or horizontal piping, but be sure the motor sha� must be always at horizontal posi�on. Arrows on the pump housing indicate the liquid flow direc�on through the pump.
Electrical connection The electrical wiring must be installed strictly in accordance with the regula�ons of na�onal electrical codes and local codes. •Electrical installa�on should be conducted by a qualified electri- cian. •Always make sure electric power is disconnected before wiring the circulator.
Control panel Elements on the control panel The control panel on the AHW(S) Circulator includes: posi�on descrip�on Display showing the actual pump power consump�on in Wa�. Seven light fields indica�ng the pump se�ng Mode Select bu�on for changing pump se�ng...
The display shows the actual pump power consump�on in Wa�s. Display The AHW(S) Circulator has eight pump se�ngs which can be selected with the press bu�on. Every �me the Mode bu�on is pressed the pump se�ng is changed to the next op�on.
Page 9
Start Up Pump settings and pump performance 4 Meter pump curve...
Page 10
Start Up Pump settings and pump performance 6 Meter pump curve...
Page 11
Highest constant pressure curve Func�on CP2 pressure curve depending on the load demand. Speed III is the highest constant speed performance curve of AHW(S) Func�on III Highest constant speed III Circulator and it also presents the max performance capability of the pump.
Page 12
Self protection 1.Overload protection Overload leads low RPM to avoid high working current. The motor turns off on account of low RPM, and it a�empts to turns on. 2.High Temp. protection If the Temp. of motor reaches 120C, it stops. A�er the temp. of motor cooling down, it turns on.
8. Technical data Freq. Max.Flow Max.Head Max.Power Max.Working Max. Max. Phase Model Voltage (Hz) (L/min) Pressure(PSI) Water temp Am temp ø AHW(S)-25-40-130 50/60 Single 220-240V 110°C 50°C AHW(S)-25-40-180 50/60 Single 220-240V 110°C 50°C AHW(S)-25-60-130 50/60 Single 220-240V 110°C 50°C AHW(S)-25-60-180 50/60 Single 220-240V 110°C...