Before starting work on the pump, make sure that the electricity supply has been switched off and that it cannot be accidentally switched on.
Cause
Problem
Remedy
1. pump does
a. No power supply
Connect the electricity supply
not start
b. Wrong voltage
Check if supply voltage is correct.
c. Inadequate pressure
Adjust pressure per "ADJUST PRESSURE
setting
SWITCH" in the Manual.
d. Seized-up pump
Place a screwdriver against the shaft end
of the motor to check it the rotor will spin
freely, and contact your pump supplier.
2. Pump cuts
a. Seized-up pump
Same as above
out during
b. Overloaded/
The pump will start after motor cooling
operation
overheated motor
down. If it doesn't, or the problem
happens too frequently, please contact
your pump supplier.
c. Poor water supply
Check if water supply is adequate and
if the inlet pipe is blocked.
3. Pump starts
a. Existing pipe is leaking
Fix the leakage.
when no
b. Defective check valve
Clean or replace with a new valve.
water is
consumed
c. Pump suck in air.
Check the suction pipe and water supply.
*If your problem can not be fixed by the suggested remedy, please contact your pump supplier.
This Product is warranted to the first user only to be free of defects in material and workmanship for a period of 12 months from date of
installation, but no more than 18 months from date of manufacture. Our liability under this warranty shall be limited to repairing or
replacing at our election, without charge, FOB Our distribution center or authorised service agent. We will not be liable for any cost
of removal, installation, transportation or any other charges that may arise in connection with warranty claim.
The warranty period commences on the date of original purchase of the equipment. Proof of purchase and installation date, failure date, and
supporting installation data must be provided when claiming repairs under warranty.
This warranty is subject to due compliance by the original purchaser with all directions and conditions set out in the installation and operating
instructions. Failure to comply with these instructions, damage or breakdown caused by fair wear and tear, negligence, misuse, incorrect
installation, inappropriate chemicals or additives in the water, inadequate protection against freezing, rain or other adverse weather conditions,
corrosive or abrasive water, lightning or high voltage spikes or through unauthorised persons attempting repairs are not covered under warranty.
We will not be liable for any incidental or consequential damages, losses, or expenses, arising from installation, use, or any other causes.
There are no express or implied warranties, including merchantability or fitness for a particular purpose, which extend beyond those
warranties described or referred to above.
Certain countries do not permit the exclusion or limitation of incidental or consequential damages or the placing of limitations on the duration of
an implied warranty, therefore, the limitations or exclusions herein may not apply. This warranty sets forth specific legal rights and obligations,
however, additional rights may exist, which may vary from country to country.
Supersedes all previous publications.
STAIRS INDUSTRIAL CO., LTD
No. 3-8,Sanchial Tsun, Lutsao Husiang, Chiayi Hsien, Taiwan
Tel: +886 5 3750488 Fax: +886 5 3752330
E-mail: stairs@stairs.com.tw Web Page: www.stairs.com.tw
Cause
Problem
4. Pump starts
a. Leakage in suction
Check the suction pipe and water supply
and stops too
pipe or air in the water.
frequently
Set your tap on a higher water flow.
b. Discharge flow is too low.
5. Electric shock
a. Ineffective grounding
Reactivate grounding.
6. Pump does
a. Poor water supply or
1. Turn off the power supply and open
the refilling plug to release the air.
not stop when
air suck in.
Then restart.
water is not
consumed
2. In case of long suction pipes, turn off
the power and make sure if water
supply is adequate.
b. Pressure setting is too
Adjust pressure per "ADJUST
high
PRESSURE SWITCH" in the Manual.
c. Existing pipe is leaking
Fix the leakage.
7. Pump runs
a. 3-phase motor runs in
Switch any of the 2 wires from motor
normal but
wrong rotation.
terminal to correct rotation.
with very low
b. Poor water supply
Check if water supply is adequate and if
discharge flow
the inlet pipe is blocked.

Limited Warranty:

Remedy

LIQUIDS TO BE PUMPED

These pumps are designed for the pumping of non-aggressive water, or water not containing solid particles.

OPERATING CONDITIONS

Ambient temp.
: Max. +40ºC (104ºF) for cold water series Max. +90ºC (194ºF) for hot water series
Water temp.
: +2ºC (36ºF) ~ +40ºC (104ºF)
System pressure : SSA200W,300W,400W Max. 5 kg/cm² (70 PSI) SSA600W,800W Max. 7 kg/cm² (99 PSI)
Relative humidity: Max. 85% (RH)

INSTALLATION

1. The pump foundation should be rigid enough to absorb any vibration from the motor, and the pump should be securely bolted to the foundation.
2. It is recommended that the plumber/installer provides an adequate draining system to avoid damage in case of leakage, particularly when
installed indoors. When it is installed outside, it should be covered by a weather-proof housing, well ventilated to allow motor heat to escape.
3. The pump should be installed as close as possible to the water source.
4. When use with water heaters, a check valve should be installed between pump (discharge) pipeline and water heater to avoid high-pressure steam
backflow. Besides, negative inlet pressure application is required to avoid cavitation.
6. It is recommended to shut off the pump when the water source is unavailable; although it has the dry run cut off function.
7. The pump has a built-in check valve. It is not necessary install any other valve on the suction.
8. To avoid your furniture damage, do not install the pump on ceiling, carpet or any place close to electrical appliance, outdoor installation must covered by tent.

PIPING

1. The suction line should be installed as short and straight as possible, with a minimum of bends. The internal diameter of the suction pipe must be
equal to, or greater than the ports of the pump.
2. For suction lift over 4 meters, the suction pipe should be of greater diameter than the suction port.
3. The protective rubber films within the center of the suction/discharge flange gaskets must be removed before installation.
4. Be careful not to allow any foreign objects (PVC adhesive gum, dirt, sand etc.) into the pump, otherwise the pump will not operate correctly. To
prevent this problem, it is recommended to use a strainer which already comes with the product.
Installation and
Operating
Instructions
SSA Series
DEAR CLIENT,
Congratulations on your purchase of this product. Like all Our
products, we had developed it with the latest technologies and produced it
with the most advanced manufacturing process and the best quality parts.
Please do read all instructions carefully before installing your new product,
as failures caused by incorrect installation or operation are not covered by
CCAAPB0E02
the warranty.
Water pH range : 5.5 ~ 8.5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SSA-200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Stairs SSA-200

  • Page 1: Limited Warranty

    4. Be careful not to allow any foreign objects (PVC adhesive gum, dirt, sand etc.) into the pump, otherwise the pump will not operate correctly. To Tel: +886 5 3750488 Fax: +886 5 3752330 E-mail: stairs@stairs.com.tw Web Page: www.stairs.com.tw prevent this problem, it is recommended to use a strainer which already comes with the product.
  • Page 2 1. The pump should be shut down and the trouble corrected if the pump is running at speed and found to have any of the following problems: suggestion maximum pressure range as below. • No water discharged (Green light flash) • Not enough water discharged SSA-200(H) - 2.0 kg/cm² (28 psi) SSA-300(H) - 2.5 kg/cm² (35 psi) SSA-400(H) - 3.0 kg/cm² (42 psi) • Excessive vibration •...

This manual is also suitable for:

Ssa-300Ssa-400Ssa seriesSsa-600Ssa-800Ssa-200h ... Show all

Table of Contents