  • Page 1 Sauna climate unit Saunum BASE / BASE Short / BASE S...
  • Page 2: Table Of Contents

    Installation _________________________________________ Dimensions of the Saunum BASE / BASE Short models_________ Saunum BASE / BASE Short model installation distances_______ Components of the Saunum BASE / BASE Short device ________ Saunum BASE S model dimensions_______________________ Saunum BASE S model installation distances________________...
  • Page 3 Saunum Saunas OÜ will not be held liable who is qualified to perform electrical The BASE / BASE Short / BASE S sauna of the Device under normal transport condi- for various side effects to the health of the work.
  • Page 4: Installation

    NB! Read the Safety Information before Figure 1 beginning installation (see pp 4–5)! Dimensions of the Saunum BASE / BASE Short models. The Device is installed on the wall of the steam room or behind the inner lining (if 0.3 in...
  • Page 5: Saunum Base / Base Short Model Installation Distances

    Figure 1A - Saunum BASE / BASE Short model installation distances. Figure 1B - Saunum BASE / BASE Short model installation distances. DEVICE WALL MOUNTED INSIDE OF WALL WALL-MOUNTED DEVICE 0.5 in distance 7.8 in distance 0.5 in distance 7.8 in distance...
  • Page 6: Components Of The Saunum Base / Base Short Device

    Figure 1C - Components of the Saunum BASE / BASE Short device. The Device works most efficiently when the be able to carry the weight of at least 77 edge of the upper airing vent opening is lb and allow the supplied hanging strips to adjacent to the ceiling of the steam room be fastened with screws.
  • Page 7 Figure 1E - Recommended instal- 4. Install the salt balls. The salt balls are lation of the Saunum BASE / BASE placed in the Device after it has been Short model using a hanging strip. mounted on the wall. To install the balls,...
  • Page 8: Saunum Base S Model Dimensions

    FRONT VIEW REAR VIEW Figure 2 4.4 -6.9 in 11.8 in Saunum BASE S model dimensions. 9.8 in 4.5 in SIDE VIEW 0.3 in BOTTOM VIEW Cable opening 7,9 in 8.9 in 16.7 in...
  • Page 9: Saunum Base S Model Installation Distances

    Figure 2A - Saunum BASE S model installation distances. Figure 2B - Components of the Saunum BASE S model device. ADDITIONAL AIR DAMPER DEVICE WALL MOUNTED INSIDE OF WALL 0.6 in distance 7.9 in distance 1.9 in from the wall...
  • Page 10 Figure 2C - Recommended instal- 5. Place the salt balls. The salt balls are lation of the Saunum BASE S model placed in the Device after it has been using a hanging strip. mounted on the wall. To place the balls,...
  • Page 11 ATTENTION! The Device must be ins- to prevent water from entering the Device Figure 3A – Connecting the power cable Figure 4 – Connecting the power cable talled by a person who is qualified to along the cable. The external insulation lay- to a Device equipped with an internal fan to a Device equipped with an external fan perform electrical work, in accordance...
  • Page 12 Figure 5 – Wiring diagram. Figure 6 – Wiring diagram: Device, equipped with illumination and a switch. FAN SAUNUM M001 FAN HOUSING DEVICE HOUSING FAN SAUNUM M001 FAN HOUSING DEVICE HOUSING POWER/SPEED 120 VAC FAN POWER INPUT TERMINAL NB! CONNECTION ONLY PERMITTED THROUGH...
  • Page 13: Instructions For Use

    • if all tools and residues of the time as the fan (see the marking on the the base tray located between the air dis- located on the bottom front panel of the packaging of the Device) when the Device materials used during installation charge grille and the fan.
  • Page 14: Warnings

    Generally, the fan does not need to be lation in the steam room. Saunum must come to a complete stop. cleaned more than once a year. Only quali- is not responsible for possible cor- •...
  • Page 15: Warranty

    4. Damage caused by misusing the low quality of assembly, the recommended Heater type: _____________________________________________________________ Device; repair partners of Saunum will repair or replace the Device or its defective part 5. Damage caused by improper Sticker / serial number: without charging for labor and spare parts installation of the Device;...
  • Page 16 EC Declaration of Conformity Manufacturer: Saunum Saunas OÜ Address: Läike tee 2-4 75312 Tallinn, Estonia certifies that the product: Indoor climate unit in the sauna steam room complies with the requirements set forth in the following directives of the European Council, provided that the installation has been carried out in accordance with the installation instructions issued by the equipment manufacturer and the instructions EN 60 204-1 ‘Safety of Machinery.