Symbol
A
Directly below an opening, air brick, opening windows, etc
B
Above an opening, air brick, opening window, etc.
C
Horizontally to an opening, air brick, opening window, etc.
D
Below plastic gutters, soil pipes, drain pipes, etc.
E
Below eaves
F
Below balconies or car port roof
G
From vertical drain pipe or soil pipe
H
From and internal or external corner
I
Above ground, roof or balcony level
J
From surface facing the terminal
K
From terminal facing terminal
L
From opening in the car port (eg door, window etc) into the dwelling
M
Vertically from terminal on the same wall
N
Horizontally from terminal on the same wall
O
From the wall on which the terminal is mounted
P
From a vertical structure on the roof
Q
Above intersection with the roof
BS 5440
26
Enfocus Software - Customer Support
Terminal Position
Dimensions
300mm
300mm
300mm
75mm
200mm
200mm
150mm
300mm
300mm
600mm
1200mm
1200mm
1500mm
300mm
N/A
0