Using the pipes present inside the accessories box, make
the remaining hydraulic connections between the boi-
ler unit (a), the single-zone hydraulic unit (c) and the
Magis Combo Plus V2 indoor unit (G), as shown in Fig. 21.
For easier assembly, start with the pipes closest to the rear wall
up to those closest to the installer, remembering to interpose the
appropriate gaskets supplied.
Attention: some components required to complete the hydraulic
connections are located inside the accessories box of the Magis
Combo Plus V2.
Assemble the sanitary probe fig. 21 by inserting it in its seat.
At the end of the installation, insulate all the connections with the
material present inside the accessories box.
AC
MU
a
MU
RU
21
G
AF
R
M
h
c
79
Need help?
Do you have a question about the BASIC MAGIS PRO and is the answer not in the manual?
Questions and answers