  • Page 1 FTS 812(L) USER MANUAL FTS 812(L) LED Approach Lighting System (REIL/RTLS) Reference Manual Part Number F7918000 Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 2: Front Matter

    While every effort has been made to ensure that the information in this manual is complete, accurate and up-to- date, Flash Technology assumes no liability for damages resulting from any errors or omissions in this manual, or from the use of the information contained herein. Flash Technology reserves the right to revise this manual without obligation to notify any person or organization of the revision.
  • Page 3: Personnel Hazard Warning

    Dangerous line voltages reside in certain locations in this equipment. Also, this equipment may generate dangerous voltages. Although Flash Technology has incorporated every practical safety precaution, exercise extreme caution at all times when you expose circuits and components, and when you operate, maintain or service this equipment.
  • Page 4: Table Of Contents

    Wiring the System Power and Communications Connections ..............12 Verifying Operation ............................ 14 2.7.1 Power Up ............................... 14 Section 3 – Beacon Operation ............................. 14 System Overview ............................14 User Interface Board ..........................14 Control Section: ..............................15 Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 5: List Of Figures

    Table 4.1 – Troubleshooting - Beacon is in Alarm, is Not Flashing Correctly, or is Not Flashing ......... 17 Table 4.2 – Troubleshooting – 1 or 2 Beacons Do Not Flash ..................17 Table 5.1 – Spare/Replacement Parts ......................... 19 Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 6: Section 1 - Overview

    12.9 lbs. (no flash head mounting brackets) 384 x 201 x 295 mm. 5.9 kg. Table 1.1 – Weights and Dimensions * Weight does not include 2” EMT conduit or any fittings below it. Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 7: Performance Characteristics

    The power converter has internal timing circuitry to fix the instant at which it flashes. This signal also contains encoded flash intensity information. A control line, which enables sequential flashing, interconnects the lights. Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 8: Component Identification

    FTS 812(L) USER MANUAL 1.3 COMPONENT IDENTIFICATION LED PCB Humidity Control Cable Connector Figure 1.1 – FH 800 (L) External Views Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 9: Section 2 - Unpacking, Installation, Mounting, Wiring And Checkout

    The FTS 812(L) is packaged in custom packaging to ensure that it arrives safely and undamaged at the installation location. Unpack all hardware and inspect for damage. Please contact Flash Technology Customer Service (page 18) if any parts are damaged or missing. See the RMA Policy (page 19) for additional information.
  • Page 10: Warning

    Aim each LED FH using the external vertical and horizontal leveling guides Tighten hardware to lock assembly into place Power the system ON and verify operation (local & remote) and user settings After all steps are completed successfully, the installation is finished Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 11: Install The Co-Mount And Remote-Mount Units

    2” EMT FITTING (SUPPLIED) LEVEL FLASH HEAD FRANGIBLE FITTING (SUPPLIED) (WITH 2” MALE NPT) 2” FEMALE NPT FLANGE FITTING (SUPPLIED BY CUSTOMER) CONCRETE PAD (SUPPLIED BY CUSTOMER) Figure 2.2 – System Dimensions and Mounting Details Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 12: Aiming The Fh 400(L) Flash Heads

    The short pigtail is routed down through the cable gland between the conduits and out to the co-mounted flash head as shown in Figure 2.2. Input power connections required are power (100-240 VAC, Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 13: Figure 2.3 - System Input Wiring

    812(L) system. This switch should accommodate switching of the 24 volt remote DC + power provided by the PC 800(L) terminal block. Figure 2.3 – System Input Wiring Figure 2.4 – System Wiring Diagram Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 14: Verifying Operation

    The user interface board is located inside the PC 800(L) enclosure and controls the operational parameters of the REIL system. Refer to Figure 3.2 for a graphical reference to the sections listed below. Figure 3.2 – User Interface Board Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 15: Control Section

    Press the button to select between 16ms, 33ms and 66ms intervals between flashes in a sequenced approach system. This setting in not used for REIL systems. The default for this setting is 16ms. Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 16: Intensity Step Configuration Section

    4.1 MAINTENANCE No regularly scheduled maintenance is required for the beacon. • Flash Technology warranties the light output of the beacon to meet or exceed FAA requirements for a 5-year period. • Periodic cleaning of the lens is recommended with soapy water or any acrylic cleaning solution. No other cleaning solutions are recommended.
  • Page 17: Troubleshooting

    Go to Step 2g. Is 24VDC available at the beacon end of the Replace the beacon. pigtail for the beacon that is not flashing? Check pigtail, replace as needed Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 18: Flash Head Repair Procedures

    Replacement is the reverse of the removal process. SECTION 5 – CUSTOMER SUPPORT 5.1 CONTACT INFORMATION Customer Service: 1-800-821-5825 Telephone: (615) 503-2000 Fax: (615) 261-2600 Website: flashtechnology.com Shipping Address: Flash Technology 332 Nichol Mill Lane Franklin, TN 37067 Flash Technology, LLC Revision 1 – 2/10/2022...
  • Page 19: Ordering Parts

    5.4 SYSTEM ORDERING CODE The following table provides a breakdown of the series scheme for the Flash Technology Airfield LED product. The first digit corresponds to an Omni or Uni-directional beam spread, the second indicates either a voltage or CCR driven power supply and the remaining digits describe how many lights are in the complete system (2-21).
  • Page 20: Rma Policy

    FTS 812(L) USER MANUAL 5.3 RMA POLICY If any system or part(s) purchased from Flash Technology needs to be returned for any reason (subject to the warranty policy), please see the current RMA policy available online at flashtechnology.com/rma To initiate an RMA, call the Flash Technology Technical Support at 1-800-821-5825, option 9. Tech Support is available M-F, 7 a.m.