FTS 812(L) REIL/RTIL Installation Quick Start Guide
Each FTS 812(L) system includes two LED ashheads and one power converter/controller.
The PC 810(L) power converter has an integrated controller with on-board user interface
1
2
1
Power supply - Provides power to both LED flashheads (24VDC output), integrated controller and user interface board.
2
Input power and fuse block - Input voltage range of 120 - 240VAC (50/60Hz). Two 220V, 40kA fuses provide surge
protec�on.
3
User interface board - Controls the opera�onal parameters of the ligh�ng system including; mode selec�on, alarms,
flash rate and custom configura�ons.
4
Terminal block - Interface for remote user controls, the LED flashhead 24VDC power and RS-485 communica�ons outputs.
Damage will occur if the DC polarity of the flashhead cable is reversed. Pay close a�en�on to guides and labels.
The FH 800(L) comes pre-installed on the remote-mount bracket assembly
FH 800(L)
Front
1
Flashhead cable connec�on - Provided FH cable connects to the back of the FH 800(L). Use the twist lock connector to
secure. Pay close a�en�on to the cable labels before install to avoid delays and re-work.
2
Bubble level - Each system comes with one removable bubble level. Both bracket types include a circular cutout to
hold the included level. Physically move the level to the fixture being installed.
1
2
3
4
FH 800(L)
Back
P/N F7904241 REV A

Advertisement

loading

Summary of Contents for Flash Technology FTS 812 REIL

  • Page 1 FTS 812(L) REIL/RTIL Installation Quick Start Guide Each FTS 812(L) system includes two LED ashheads and one power converter/controller. The PC 810(L) power converter has an integrated controller with on-board user interface Power supply - Provides power to both LED flashheads (24VDC output), integrated controller and user interface board. Input power and fuse block - Input voltage range of 120 - 240VAC (50/60Hz).
  • Page 2 Remote-mount Assembly Installation Steps In this assembly, one LED ashead (FH 800(L)) is mounted to a bracket. A single cable will feed from this assembly to the co-mounted xture. Ensure the installed height does not exceed 34”. Damage will occur if the DC polarity of the flashhead cable is reversed. Pay close a�en�on to guides and labels. 1.

This manual is also suitable for:

Fts 812 rtilFts 812 l reilFts 812 l rtil