6. Installation

It is recommended that tapping saddles (not included, to be purchased separately) are fitted on pipes for measurement water
connection points to and from MiniMaster, and for dosing points for liquid acid and chlorine via hose pumps.
A flexible PVC hose (included) must run between the MiniMaster and pre-filter. A rigid PE hose (included) must run between the
pre-filter and the pipes.
1. Fit the MiniMaster against a wall.
2. Fit the accompanying connections on the Minimaster, see figs. 2 and 3:
Remove the saddle (M), fold the modules forwards, screw the connections tight to the MiniMaster's inlet and outlet.
3. Assemble the pre-filter, see instruction MA60-22. NB The cover on the filter has an arrow indicating the direction of flow.
4. Fit the pre-filter in a suitable position close to the MiniMaster.
5. Cut the accompanying flexible PVC hose to appropriate lengths and connect them, without sharp bends, between the Mini-
Master and pre-filter.
A small piece of flexible hose may also be fitted to the measurement water outlet if required.
6. Inlet A: Fit a tapping saddle after the sand filter (see A Figure 4) on the pressure side of the pool circulation pump.
7. Outlet B: Fit a tapping saddle after the overflow (see B Figure 4) on the suction side of the pool circulation pump.
8. Cut the accompanying rigid PE hose into two appropriate lengths, fit hose couplings on both ends.
9. Connect one hose to the pre-filter and inlet A. Use a thread seal when connecting to the tapping saddle/pipe.
10. Connect the other hose to the pre-filter and inlet B. Use a thread seal when connecting to the tapping saddle/pipe.
Alternative location of outlet B: route the hose direct down into the overflow (C, Figure 4).
11. If dosing pumps are used for liquid chlorine and acid/alkali, the dosing points must be located at least 500 mm apart,
after other equipment for heating/other disinfection. Chlorine dosing must always be positioned last.
Fig. 1. Pre-filter
Measurement water cock N
Meassurement water outlet
PVC hose
Fig. 3.
Fig. 4.
C
1. Skimmer
2. Main drain
3. Inlet
4. JetSwim
5. Light
6. Circulation pump pool
(secondary flow)
7. Filter
8. Heat exchanger
9. Non-return valve
10. Drain
11. Circulation pump hot water
(primary flow)
12. Boiler
13. MiniMaster
14. Pre-filter MiniMaster
15. Chlorine dosing
16. Chlorine
17. Acid/alkali dosing
18. Acid/alkali
19. Salt chlorinator
Ball valve L2
PE hose
2
Pool
Pool
3
4
1
MiniMaster
MiniMaster
1
5
2
B
7
6
10
L2
L1
Ball valve L1
PVC hose
1
MiniMaster
Pool
2
PE hose
Sid 3.
3
4
5
A
8
11
9
10
12
ENGLISH
Fig. 2. MiniMaster
MiniMaster
Pool
Till MA60-16
15
16
17
9
18
12
Surface treatment
E
The tolerance class in accordance with th
part of ISO 2768-1
Mi
Mi
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
13
14
19

Advertisement

Table of Contents
loading

Table of Contents