Description of IC Terminal

TMP87C847UG :
IC5002
No.
Symbol
1
SHORT_1(PULL-UP)
2
SHORT_2(PULL-UP)
3
SHORT_3(PULL-UP)
4
DATA_IN2(PULL-UP)
5
iLIMIT_1
6
iLIMIT_2(PULL-UP)
7
iLIMIT_3(PULL-UP)
8
iLIMIT_4(PULL-UP)
9
DC_OFFSET_1(PULL-UP)
10
DC_OFFSET_2(PULL-UP)
11
DC_OFFSET_3(PULL-UP)
12
DC_OFFSET_4(PULL-UP)
13
TEST(GND)
14
RESET
15
XIN
16
XOUT
17
VSS
18
VAREF
19
AD_VOLT
20
AD_THRM1(u-com)
21
AD_THRM2(TRANS)
22
+VCC_REF
23
OUT_THRM_1
24
OUT_THRM_2
25
OUT_THRM_3(GND)
26
OUT_THRM_4(GND)
27
WATCH_DOG(NC)
28
DATA_OUT(C)
29
DATA_IN_1(PULL-UP)
30
AMP_STATE(PULL-UP)
31
DATA_IN(B)(PULL-UP)
32
DATA_IN(C)(PULL-DOWN)
33
POWER_1
34
LED_PROTECT(PULL-UP)
35
DATA_OUT(B)(PULL-UP)
36
DATA_OUT(A)(PULL-UP)
37
BATT_DET
38
SHORT_4(PULL-UP)
39
D_AMP_MUTE
40
VDD
41
POWER_2
42
D_AMP_STB
43
LED_POWER(PULL-DOWN)
44
2nd_V_DET
All manuals and user guides at all-guides.com
I/O
-
Pull-up connect terminal.
I
Output overcurrent detection terminal-1.
-
Pull-up connect terminal.
-
GND connect terminal.
I
RESET terminal.
I
Crystal oscillator connection terminal.
O
-
GND connect terminal. (A/D converter basis ground)
-
Reference voltage of A/D converter terminal.
I
Power supply voltage detection terminal. (A/D input)
I
Ambient temperature of u-COM detection terminal. (A/D input)
I
TRANS temperature detection terminal. (A/D input)
I
The second voltage reference value input terminal. (A/D input)
I
Output element temperature detection terminal-1. (A/D input)
I
Output element temperature detection terminal-2. (A/D input)
-
GND connect terminal.
-
No connect terminal.
O
-6dB Level Down circuit control terminal.
-
Pull-up connect terminal.
-
Pull-down connect terminal.
O
Power circuit control terminal.
-
Pull-up connect terminal.
I
BATT-DET terminal.
-
Pull-up connect terminal.
O
PWM device MUTE control terminal.
-
Power supply terminal.
O
TL494 control terminal.
O
PWM device STANDBY control terminal.
-
Pull-down connect terminal.
I
The second voltage detection terminal.