■ Correct sensor positions for heating with double
temperature measurement and ΔT monitoring.
T1 (main temperature) on the bore.
T2 on the outer ring.
CAREFULL!
Handle the sensor with care! It is a vulnerable part of
the heater. After use, place the sensor on the side of a
vertical pole. Remove the sensor from the workpiece at
the plastic part. Do not pull the cable.

8. Method of operation

WARNING!
■ Use suitable lifting equipment for heavy
ledges and workpieces. Prevent personal
injury by improper handling.
■ The weight of the workpiece may not exceed
the value given in section 8.3 and in the
technical specifications. This can cause
failure of the device and personal injury.
■ Ensure that the power supply cable cannot
come into contact with the workpiece to
be heated. Damage to the cable can cause
electrocution!
■ Never use a metal strap to support
workpieces or suspend them in the magnetic
field. High currents could start running
through the strap, causing it to heat up.