CAUTION:
Never use materials that could damage the lid, the paint or the tank such as abrasive cloth or
any other metallic article.
Only the tank is waterproof! Liquid overflows somewhere else could damage the device.
2.5. « Stuck » lid
If the device is switched off while there is cocoa butter between the tank and the lid, the latter
may get stuck to the tank after it has hardened. In this case, switch on the device and reheat
until butter turns into cream again.
Never force the lid open!

2.6. Calibration

Magic Temper® is factory calibrated. It is recommended to recalibrate it every year or if a deviation
occurs. Calibration can only be performed by an authorized person. Contact your retailer.
The calibration period can be set in the application settings.

2.7. Button colours

White: device connected to the application (or communicating with the application)
Blue: tank temperature is reaching the set temperature
Green: set temperature is reached
Red: cleaning mode activated or problem detected