9-2. Instruction of troubleshooting
Start
Indoor unit
operates.
Outdoor unit
doesn't
operate.
Outdoor unit
doesn't
Outdoor unit
operate
operates in
even in
only Test Run
Test Run
operation.
operation.
Check room
temperature
Refer to
thermistor.
Refer to 9-6.
"Check of
"Test point
outdoor unit".
diagram and
voltage".
Flash on and
2-time flash
off at 0.5-
Cause:
second
Indoor unit
interval
• Trouble of
Cause:
room
Indoor/
temperature/
Outdoor unit
indoor coil
• Mis-wiring
thermistor
or trouble of
serial signal
Check room
Refer to 9-5.E
temperature
"How to
thermistor
check mis-
and indoor
wiring and
coil
serial signal
thermistor.
error (When
Refer to 9-6.
outdoor unit
"Test point
doesn't
diagram and
work)".
voltage".
As for outdoor unit MUCFH type, refer to the service manual OB381.
As for outdoor unit MXZ type, refer to the service manual OB319 REVISED EDITION-A.
All manuals and user guides at all-guides.com
Indoor unit
operates.
Outdoor unit
doesn't operate
normally.
Unit doesn't
Outdoor unit
operate
doesn't
normal
stop even
operation in
if indoor unit
COOL or
stops.
HEAT mode.
Refer to
Refer to
"Check of
"Check of
outdoor unit".
R.V. coil".
4-time flash
MXZ type
5-time flash
Cause:
Cause:
Indoor unit
Outdoor unit
• Trouble of
• Outdoor
indoor
power
electric
system
P.C. board
abnormality
Refer to 9-5.
Refer to
D "Check
"Check of
of indoor
inverter/
electric
compressor"
control P.C.
and "Check
board".
of power
supply".
12
Indoor unit
doesn't receive
the signal from
remote controller.
Indoor unit
Indoor unit
doesn't operate,
operates, when
when the
the EMERGENCY
EMERGENCY
OPERATION
OPERATION
switch is pressed.
switch is pressed.
1. Check indoor /
Refer to 9-5. B
outdoor
"Check of
connecting wire.
remote controller
2. Refer to 9-5. C
and receiver
"Check of indoor
P.C. board".
electronic control
P.C. board".
6-time flash
MXZ type
MUCFH-GA60VB
Cause:
7-time flash
Outdoor unit
Cause:
• Trouble of
Outdoor unit
thermistor
• Trouble of
in outdoor
outdoor
unit
control
system
Refer to
MUCFH-GA60VB
"Check of
Replace the
outdoor
deicer
thermistor".
P.C. board.
MXZ type
Replace the
outdoor
electronic
control
P.C. board.
OPERATION INDICATOR
lamp on the indoor unit is
flashing on and off.