Device Installation/ 设备安装
E Wall-mounted Installation/ 壁装
Place the wall-mount bracket to the required installation location,
1
a marker to mark the screw installation positions and drill holes in the
marked positions.
将壁装支架放置于安装位置,使用记号笔绘制螺钉安装位置,并根据绘制的螺
钉安装位置钻孔。
F Cable Connection/ 连接线缆
CAUTION/ 注意
• In areas prone to lightning strikes, the lightning arrester must be installed and grounded.
在易受雷击的区域,必须安装避雷器,避雷器必须接地。
Strong and weak current cables must be kept at least 5 cm apart from each other. When connecting the cables
to the device, take care to avoid connecting strong current cables to weak current interfaces or you will damage
your device.
强电和弱电必须分开布线,两者间的距离不小于 5cm。线缆与设备连接时,禁止将强电接到弱电接口上,以免造成设备损坏。
• Wrap all pigtail cables in insulated, waterproof, rubber tape to prevent short circuits or water damage. Cutting
off the pigtail cables will void your warranty.
请务必使用绝缘胶带和防水胶带对所有尾线进行绝缘和防水处理, 以免造成短路和漏水。 尾线不能剪断, 若剪断, 则无法维保。
Connect the power cable and the ground cable. A bare wire supports the 1.5 mm² (length is less than or equal
1
to 25 m) power cable at most, and a crimping terminal supports the 1.0 mm² (length is less than or equal to
20 m) or 0.75 mm² (length is less than or equal to 15 m) power cable. The ground impedance must be less
than or equal to 5 ohms.and the ground cable length is less thanor equal to 25 meters. Use the OT terminal
with an inside diameter of 3 mm.
连接电源线和接地线。接裸线最大支持 1.5mm²(长度最大支持 25m)电源线,配压线端子支持 1.0mm²(长度最大支
持 20m) 或 0.75mm² (长度最大支持 15m)
电源线。
Power cable
电源线
Ground cable
接地线
use
Obtain a drill bit with a 5 mm diameter and drill four 35 mm holes in the
2
specified positions marked by the
an expansion bolt into the hole.
依照标记得位置,选择直径为 5mm 的钻头,钻取深约 35mm 的导孔,并使
用羊角锤将膨胀螺栓打入钻好的孔内。
接地线要求阻抗≤ 5Ω, 长度≤ 25m,
用内径大小为 3mm 的 OT 端子。
Thread the cables through the ceiling-mount bracket. Put the four
3
marker.
Use a claw hammer to install
expansion bolts through the four screw holes at the bottom of the
ceiling-mount bracket, and tighten the screw.
将需要与摄像机尾线对接的线缆穿过吊装支架。将吊装支架底座上的 4 个螺
孔套在相应的膨胀螺栓上,拧紧螺钉。
NOTE/ 说明
For details about subsequent installation
operations, see steps 4 to 6 in C Ceiling-
mounted Installation.
后续安装的具体过程请参见"C 吊装"中的步骤
4-6。
Connect the network cable. Loosen the components 1, 2, and 3 of the waterproof connector kit on the network
2
cable port in sequence, thread the network cable through the kit, and install the components in the sequence
marked in the following figure. The waterproof connector of the network cable must be secured tightly, or
they may come loose later.
连接网线。先把网线接口上防水套件的组件 1、组件 2 和组件 3 依次旋转拆卸,然后穿入网线,再将各组件按如图所示
顺序安装。网线防水接头务必拧紧到位,否则会有脱落风险。
1
O-ring for the waterproof connector (rubber ring)
网线防水接头密封圈(细橡皮圈)
3
Connect the alarm cable. It is recommended that twisted pair cables be
used as alarm cables. The diameter of the cable core ranges from 22
AWG to 28 AWG. The impedance of the entire cable is less than or equal
to 100 ohms.
连接告警线缆。告警线缆建议使用双绞线,线芯的线径为 22AWG ~ 28AWG,
整条线路的阻抗≤ 100Ω。