NOTE: The power supply must be mounted in the appropriate (UYMR or UL approved) electrical enclosure. The power
supply can be mounted horizontally or vertically. It is recommended that at least 2 mountings screws (#8 or #10, M4 or
M5) be used to mount the power supply. Attach the ground wire (minimum 18 AWG (0.82mm
supply enclosure. The grounding and bonding of the power supply and overall sign shall be done in accordance with
National Electric Code (NEC) Article 600.
NOTE: For CSA approval, a disconnect/toggle switch of appropriate rating needs to be placed within 29.5 feet (9 meters)
of primary side of the power supply. The minimum rating of the switch must be either 120 or 220 Volts AC. The switch
must also support twice the amount of input current.
NOTE: When installing power supply, connect to the appropriate sized building breaker or disconnect device, for line and
neutral connections, in accordance with local, state or country regulations.
Power Supply Specifications
Input GEXLPS21—Voltage (VAC)
Input GEXLPS21-U—Voltage (VAC)
Input Frequency (Hz)
Input Current (A)
Output Voltage (VDC)
Output Current (ADC)
Output Power (W)
Environmental Operating Temp. Range
Environmental Humidity (Non-condensing)
Environmental Storage Temp. Range
Enclosure Specification
Damp Location Rated
Load
Tetra XL
6 LEDs/ft (~20 LEDs/m)
5 LEDs/ft (~17 LEDs/m)
Tetra Power White XL
(GEWWXHS3-32K) 3 LEDs/ft (~10 LEDs/m)
(GEWHXHS2-65K, GEWWXH2-32K)) 2 LEDs/ft (~7 LEDs/m)
NOTE: Remote mounting for up to 20 ft. (6.09m) use 14AWG (2.08mm
up to 75 ft. (22.87m) use 10AWG (5.27mm
RISK OF ELECTRIC SHOCK:
• Turn power OFF before inspection, installation or removal.
• Properly ground Tetra Power Supply enclosure.
• Shut off power at fuse box or circuit breaker before installation.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [ A ] est conforme à la NMB-005 du Canada.
6180 Halle Drive • Valley View, Ohio 44125-4635 • USA
P: 216.606.6555 • F: 216.606.6599 • www.led.com • info@led.com
Lumination, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of Lumination, LLC. The GE brand, logo, and ecomagination are trademarks of the General Electric Company.
© 2008 Lumination, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
2
) (GECLSW1), up to 40 ft. (12.20m) use 12AWG (3.31mm
2
).
WARNING!
Conforms to the following standards:
Minimum
Typical
108
120/230
108
120/230/277
47
0.75
11.7
0.2
1.0
-40°C
0%
-40°C
Dimensions
9.5 in. x 1.7 in. x 1.2 in. (241 mm x 43.2 mm x 30.5 mm)
Minimum (modules/ft/m)
72 / 12 / 3.66
75 / 15 / 4.57
9 / 3 / 0.91
9 / 4.5 / 1.37
RISK OF FIRE:
• Follow all NEC and local codes.
• Use only UL approved wire for input/output connections.
Minimum size 18 AWG (0.82 mm
For customer service & technical support, contact:
1-888-MY-GE-LED
2
)) to the base of the power
Maximum
264
305
-
63
0.32
0.26
12.0
12.3
-
5.0
-
65
+25°C
+60°C
-
95%
-
+85°C
Maximum (modules/ft/m)
480 / 80 / 24.38
480 / 96 / 29.26
51/17/5.18
51 / 25.5 / 7.80
2
),
2
)