Cc-link system low profile waterproof type remote i/o module

Advertisement

+1
60
(2.36)
0
50 1(1.96)
18.3(0.72)
26.5(1.04)
A
J65FBTA42-16DTE
POWER
PROTECT
Y8
Y9
YA
YB
YC
YD
YE
YF
6)
c
33(1.30)
4.1(0.16)
35(1.37)
External connection
LINK IN
4
2
3
1
110
130
LINK OUT
4
2
3
Terminal
resistance
1
select switch
5
UNIT POWER
1
3
DC/DC
5
2
4
Unit mounting screw
(FG)
AUX.
1
3
5
2
4
I/O connector
4-wire type sensor (source output)
Black
4
White
2
Brown
1
Blue
3
5
3-wire type sensor (source output)
Black
4
2
Brown
1
Blue
3
5
2-wire type sensor (source output)
4
Blue
2
1
Brown
3
5
Detection circuit
Load power
4
L
2
L
1
3
5
2-4.5 6 mounting screw
48(1.89)
34 0.5(1.33)
1)
6)
d
Y
Y
Y
Y
7)
Y
Y
Storage
sheet
Y
Y
M4 mounting screw
32(1.26)
Unit:mm(inch)
Communication connector
Pin
LINK IN
No.
1
SLD
2
DB
3
DG
4
DA
Communication
circuit
5
No pins
Power connector
Pin
UNIT
No.
POWER
1
+24V(UNIT)
2
Empty
Insulation
3
24G(UNIT)
4
Empty
5
(FG)
I/O connector
Pin
Signal
No.
name
1 +24V
Costant voltage
2
X1
circuit
X0
3
24G
X1
4
X0
5 Empty
1 +24V
2
X3
X2
3
24G
X3
4
X2
5 Empty
1 +24V
2
X5
X4
3
24G
X5
4
X4
5 Empty
1 +24V
2
X7
X6
3
24G
X7
4
X6
5 Empty
Connector for connection to main module
6(0.24)
Communication adapter(back)
Main module
2. Name and Setting of Each Area
No.
Item
Operating
1)
status indicator
LEDs
6(0.24)
21.7(0.85)
Transmission
2)
speed setting
switch
LINK OUT
SLD
DB
DG
DA
Empty
AUX.
Station number
3)
+24V(I/O)
setting switch
Empty
24G(I/O)
Empty
(FG)
Pin
Signal
No.
name
Terminal
1 Empty
4)
resistance
2
Y9
setting switch
Y8
3
24G
Y9
4
Y8
5 Empty
1 Empty
2
YB
YA
3
24G
Waterproof
YB
4
YA
connector for
5)
transmission
5 Empty
line *2
1 Empty
2
YD
YC
3
24G
YD
4
YC
5 Empty
Waterproof
1 Empty
6)
connector for
2
YF
power line *2
YE
3
24G
YF
4
YE
Waterproof
5 Empty
connector for
7)
input
connection *2
8) FG metal fitting For module FG terminal (tightening torque range: 78 to 118 N.cm)
Communication
9)
adapter fixing
screw
Module
10)
attachment
hole
*1: Duplicate station number cannot be set.
*2: Waterproof connector (based on IEC947-5-2, M12 type)
4)
TERMINATION
110
130
a
ON
1 2
Communication adapter(front)
8)
Communication
adapter
Description
LED name
POWER
ON: Power supply ON OFF: Power supply OFF
Lights up when the output section protection function is
PROTECT
working (During the protect operation, fuse interruption is
searched in the master unit side)
ON: Normal communication
L RUN
OFF: Communication shut off (time expiration error)
ON: Communication data error
Flash at regular intervals:
Indicates that the station number setting or
transmission speed setting switch position was
changed while power is ON
L ERR.
Flash at irregular intervals:
When the setting of the terminal resistor is wrong;
when the cable for the module or CC-Link is
affected by noise
OFF: Normal communication
X0 to X7
ON: Input/Output ON
Y8 to YF
OFF: Input/Output OFF
Setting switch status
Setting value
4
2
0
OFF
OFF
1
OFF
OFF
2
OFF
ON
3
OFF
ON
4
ON
OFF
Be sure to set the transmission speed within the above range.
Remove the communication adapter on the top part of the module to
set the transmission speed. (When shipped from the factory, all
settings are set to OFF.)
Select "10", "20" or "40" to set the tens place of the station number.
Select "1","2","4" or "8" to set the ones place of the station number.
Always set the station number within the range of 1 to 64. (*1)
(Example) Set the switches as below when setting the station number
to 32:
Station
Tens place
number
40
20
32
OFF
ON
Remove the communication adapter on the top part of the module to
set the station number. (When shipped from the factory, all settings
are set to OFF.)
The terminal resistor can be turned to the ON setting by using the
select switch.
DIP switch1
DIP switch2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
(When shipped from the factory, all settings are set to OFF.)
Silk
Connector for connecting the
a
LINK
IN
transmission line from the IN side (master
station side). (Male 4 pins)
Connector for connecting the
transmission line from the OUT side.
b
LINK
OUT
Be sure to attach the waterproof cap
when not in use. (Female 5 pins)
(Tightening torque range: 29 to 34 N.cm)
Silk
Connector for supplying power to the
c
UNIT POWER
module. (Male 5 pins)
Connector for supplying power to a load,
d
AUX.
etc. (Male 5 pins)
Waterproof connector for connection I/O signal. (Female 5 pins)
Be sure to attach waterproof cap A6CAP-WP2 (sold separately) when
not in use. (Tightening torque range: 29 to 34 N.cm)
When replacing the main body online or changing switch setting,
attach/remove the communication adapter with this screw.
(Tightening torque range: 42 to 58 N.cm)
Screw hole for module attachment. 2-4.5 X 6 length hole
(M4 attachment screw) (Tightening torque range: 78 to 118 N.cm)
5)
b
9)
Connector for connection
to communication adapter
3)
2)
10)
ON
40
20
10
8
4
2
1
4
2
1
STATION NO
B RATE
Confirmation details
Transmission speed
1
OFF
156 kbps
ON
625 kbps
OFF
2.5 Mbps
ON
5.0 Mbps
OFF
10 Mbps
Ones place
10
8
4
2
1
ON
OFF
OFF
ON
OFF
Contents
No terminal resistance
Ω
110
resistor ON
Ω
130
resistor ON
Setting prohibited
Contents
Contents