Flame retardant reflective tapes are arranged at the circumference of the jacket, hem, sleeve cuff and
bottom of trousers to ensure visibility and work safety of the firefighter.
All pockets are specially designed in accordance with the shape features and usage habit of the
firefighter. To facilitate storage and usage, there's a drain hole in the bottom of the pockets in order to
reduce the damage of the equipment caused by water, during the firefighter's duties.
You may find measurements and sizes of garments according to EN469/EN ISO 13688 in the below
table:
General size designation
B
UK
C
4. GARMENT CLASSIFICATION AND TESTS
You can find classification of these garments according to EN 469 standard and relevant performance
levels in the table below:
Heat transfer (flame)
Heat transfer (radiant)
Resistance to water penetration
Water vapour resistance
3. DESIGN PROPERTIES
LALIZAS Code
Size
A User's Height (cm)
A
B User's Chest girth (cm)
C User's Waist girth (cm)
Jacket length (cm)
TESTS
www.lalizas.com
74298
L (185B) XL (190B)
185
124
117
81
PERFORMANCE LEVELS
TEST
METHOD
LEVEL 2
HTI
EN 367
HTI
24
RHTI
EN ISO 6942
RHTI
24
EN 20811
Level2≥20kPa
EN 31092
Level2≤30m
4
74299
Range Tolerance
(cm)
190
±2.5
128
±2.0
121
±2.0
83
±1.5
MARKING
≥13s
24
Xf2
-HTI
≥4s
12
≥9s
24
Xr2
-RHTI
≥4s
12
Y2
Pa/W
Z2
2