To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a
length of heavy wire between the ground terminal and the ground source. The generators have a
system ground that connects generator frame components to the ground terminals in the AC
output receptacles. The system ground is not connected to the AC neutral wire.
If the generator is tested by a receptacle tester, it will not show the same ground circuit condition
as for a home receptacle.
Special Requirements
There may be Federal or State Occupational Safety and Health Administration (OSHA)
regulations, local codes, or ordinances that apply to the intended use of the generator. Please
consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.
• In some areas, generators are required to be registered with local utility companies.
• If the generator is used at a construction site, there may be additional regulations which must be
observed.
3) AC Applications
Before connecting an appliance or power cord to the generator:
• Make sure that it is in good working order. Faulty appliances or power cords can create a
potential for electrical shock.
• If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off
immediately. Disconnect the appliance, and determine whether the problem is the appliance, or if
the rated load capacity of the generator has been exceeded.
• Make sure that the electrical, rating of the tool or appliance does not exceed that of the generator.
Never exceed the maximum power rating of the generator. Power levels between rated and
maximum may be used for no more than 30 minutes.
NOTICE
Substantial overloading will switch off the circuit breaker.
Exceeding the time limit for maximum power operation or slightly overloading the
generator may not switch the circuit breaker OFF, but will shorten the service life of the
generator.
Limit operation requiring maximum power to 30 minutes.
For continuous operation, do not exceed the rated power.
10