Connections - Quest Engineering PR Series Owner's Manual

Table of Contents

Advertisement

PR-120 / PR-240

Connections

INPUT: Connect microphones or balanced line-level sources to mixer-amplifier balanced inputs.
Set Gain volume accordingly. Connect unbalanced line-level signals to RCA input connectors.
OUTPUT: Maintain proper polarity on output connectors.
For each output channel, connect the output EURO block terminals to the loudspeaker Ioads.
Use terminals marked
to
and COM for constand-voltage loudspeaker loads.
1
5
Connect the COM terminal to speaker negative(-) lead; connect one of the other terminals to
speaker positive (+) lead.
The impedance and output voltage are same as following Table.
PR-120
PR-240
NOTE : Impedances indicated in the table represent the total speaker system impedances.
Figure shows the way how to select impedance.
The wires of output transformer are connected to terminal on output select pcb same as follow
table.
100V
70V
25V
NOTE:These connectors are set in 100V output except US, CANADA ( 70V output )
(GND) and
for a 4-ohm loudspeaker load, or use terminals marked
4Ω / 22V
4Ω / 31V
[ output voltage and impedance]
[ How to change high impedance output voltage ]
T10
RED wire
BLUE wire
GREEN wire
BLUE wire
GREEN wire
5.2Ω / 25V
42Ω / 70V
2.6Ω / 25V
21Ω / 70V
T11
GREEN wire
RED wire
BLUE wire
RED wire
83Ω / 100V
42Ω / 100V
T10
T13
100V
RED
BLK
70V
GRN
BLK
25V
BLU
BLK
T12
T13
BLACK wire
BLACK wire
BLACK wire
Setups
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pr-120Pr-240

Table of Contents