4.0 Installation

4.1 Ambient Illumination Requirement

Make sure faces can be captured clearly.
Avoid direct sunlight and backlight .
The device should be at least 2 meters away from the light, and at least 3 meters away
from the window or door.
4.2 Installation
1.
3. Route and connect the cables and then
8
30°
30 °
3m
Place the drill template onto the wall and
then drill the holes according to it.
Drill Template
install the cable cover.
(KM3*7)
Screws
Cable Entry
Cable Cover
Direct/indirect
sunlight through
window
2. Install the gang box on the wall. Secure
the bracket onto the wall with 4 screws.
Bracket
4. Hang the device onto the bracket hook
and then tighten the screws.
2m
30 °
30 °
Gang Box
(KM3*7)
Screws
Wall

Advertisement