Parameter:
4. Sound notifications status
Description:
This parameter allows to activate sound signals but does not apply to major alarms, such as Fire, Trouble and
Low battery alarm.
Available settings:
0 - all notifications disabled
1 - casing opening notification enabled
2 - exceeding temperature threshold notification enabled
4 - lack of Z-Wave range notification
Parameter values may be combined, e.g. 1+2+4=7, means that all notifications are enabled.
Default setting:
0 (notifications disabled)
Parameter:
10. Configuration of control frames in BASIC command class
Description:
This parameter defines which frames will be sent in the 2-nd Association Group (SMOKE ALARM). The values of
BASIC ON and BASIC OFF frames may be defined as described in further parameters.
Available settings:
0 - BASIC ON & BASIC OFF enabled
1 - BASIC ON enabled
2 - BASIC OFF enabled
Default setting:
0 (both frames enabled)
Parameter:
11. BASIC ON frame value
Description:
BASIC ON frame is sent in case of smoke presence detection and Fire Alarm triggering. Its value is defined by the
parameter.
Available settings:
0 - turn off the device
1-99 - set the device to 1-99%
255 - set the last status
Default setting:
255
Parameter:
12. BASIC OFF frame value
Description:
BASIC OFF frame is sent in case of Fire Alarm cancellation. Its value is defined by the parameter.
Available settings:
0 - turn off the device
1-99 - set the device to 1-99%
255 - set the last status
Default setting:
0 (turn off the device)
Parameter:
13. Alarm broadcast
Description:
A value other than 0 means that alarms are being sent in broadcast mode, i.e. to all devices within Smoke-Con-
trol's range.
Available settings:
0 – broadcast inactive
1 – SMOKE ALARM command broadcast (2-nd & 4-th Association Group) active; casing opening notification
broadcast (3-rd & 5-th Association Group) inactive
2 – SMOKE ALARM command broadcast (2-nd & 4-th Association Group) inactive; casing opening notification
broadcast (3-rd & 5-th Association Group) active
3 – SMOKE ALARM command broadcast (2-nd & 4-th Association Group) active; casing opening notification
broadcast (3-rd & 5-th Association Group) active.
Default setting:
0 (broadcast inactive)
Parameter:
14. Associations in Z-Wave network security mode
Description:
This parameter defines how commands are sent in specified association groups: as secure or non-secure. Pa-
rameter is active only in Z-Wave network security mode. It doesn't apply to 1st Lifeline group.
Available settings:
0 - all groups sent as non-secure
1 - 2nd group sent as secure
2 - 3rd group sent as secure
4 - 4th group sent as secure
8 - 5th group sent as secure
Parameter values may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure.
Default setting:
15 (all groups sent as secure)
Parameter size:
1 [byte]
Parameter size:
1 [byte]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
1 [byte]
Parameter size:
1 [byte]