7. A successful update will be confirmed with the visual indicator changing color to green. The incorrect update process is indicated by the
visual indicator changing color to red, regardless of the reason.
8. After the software update, a self-test should be performed manually to ensure the device is working correctly.
Notes:
Update procedure needs to be performed twice in order to update the device completely.
If update fails or update time exceeds 10 minutes, please remove the battery, press and hold the B-button for 3 seconds, install the bat-
tery again and repeat an update procedure. If that does not work please contact our tech support team.
Controllers from various manufacturers can have different ways of activating the software update procedure (see controller's manual).
If the sensor has not completed the self-test successfully after the software update, please try to perform the test again. After two con-
secutive self-test attempts has failed, Smoke-Control is considered to be faulty and should be subject to service procedure.
Software update may be enabled only by user. During the update Smoke-Control does not detect fire. Once the software update is com-
pleted the device resumes normal operation.
Update will not be performed if battery level is low.
If parameter 2 value responsible for activation of casing opening notification has been set to active mode, please consider deactivating it
for the upgrade procedure duration.
12
ASSOCIATIONS
Association (linking devices) - direct control of other devices within the Z-Wave system network e.g. Dimmer, Relay Switch, Roller Shutter
or scene (may be controlled only through a Z-Wave controller).
Association allows direct transfer of control commands between devices, is performed without participation of the main controller and re-
quires associated device to be in direct range.
Smoke-Control allows for the associations of five groups:
1st group – Lifeline. Reporting device state. Only one device - Z-Wave network controller may be set in this group. It's not recommended to
modify this association group.
2nd group – Smoke Alarm. Sending the BASIC SET control command once smoke is detected. Its value may be modified in advanced param-
eters (see section XVI). Group may control up to five on/off devices.
3rd group – Tamper. Sending the notification NOTIFICATION REPORT (TYPE = BURGLAR, EVENT = PRODUCT COVERING REMOVED) to
associated devices once casing opening is detected. Up to five devices supporting casing opening command (NOTIFICATION REPORT) may
be included in this group.
4th group – Smoke Alarm. Sending the notification SENSOR ALARM REPORT (TYPE = SMOKE ALARM) to associated devices once smoke is
detected. Up to five devices supporting SMOKE ALARM command may be included in this group
5th group – Tamper. Sending SENSOR ALARM REPORT notification (TYPE = GENERAL) to associated devices once casing opening is de-
tected. Up to five devices supporting SENSOR ALARM REPORT command may be included in this group.
Note. Smoke-Control allows for controlling 5 regular or 5 multichannel devices per an association group in groups 2-5 and one device in the
1st group.
13
Z-WAVE RANGE TEST
The device has a built in Z-Wave network main controller's range tester.
To make Z-Wave range test possible, the device must be added to the Z-Wave controller. Testing may stress the network, so it is recom-
mended to perform the test only in special cases.
Communication mode of the device may switch between direct and one using routing, especially if the device is on the limit of the direct
range.
To perform a range test:
1. Make sure the sensor is powered.
2. Press and hold the B-button for 3 seconds. The visual indicator will glow white.
3. A short signal will sound.
4. Release the B-button.
5. Wait until the visual indicator glows violet, and then press the B-button briefly to start the test.
6. The visual indicator will indicate the Z-Wave network's range (range signaling modes described below).
7. To exit the Z-Wave range test, press the B-button briefly.