• CAUTION! – This manual contains important instructions and warnings for personal safety. Carefully read all parts of this manual. If in doubt, suspend installation immediately and contact Nice Technical Assistance. • CAUTION! – Important instructions: keep this manual in a safe place to enable future product maintenance and disposal pro- cedures.
INSTALLATION 3.1 - General installation notes 1. Make sure the alarm sound can be easily audible in other rooms in the building. 2. Install the sensor in already decorated, painted rooms. 3. Install the sensor at least 1.5m from air conditioners. 4.
REMOVING THE DEVICE Removing (Exclusion) - Z-Wave device learning mode, allowing to remove the device from existing Z-Wave network. To remove the device from the Z-Wave network: 1. Make sure the sensor is connected to battery. 2. Set the main controller into the removing mode (see main controller’s operating manual) 3.
Notes: • As described, Smoke-Control checks for smoke presence every 10 seconds. In addition, the device checks for malfunction and tests the Z-Wave network communication (see section VII) at each wake up interval (6 hours by default) and when sending reports, provided that range test has been enabled in advanced configuration.
Notes: • Please use this procedure only in the event that the system primary controller is missing or otherwise inoperable. • Reset procedure should remove Smoke-Control from the Z-Wave network main controller’s memory (depending on the controller’s ver- sion). • Removing the device from the Z-Wave network will reset Smoke-Control automatically.
Page 7
7. A successful update will be confirmed with the visual indicator changing color to green. The incorrect update process is indicated by the visual indicator changing color to red, regardless of the reason. 8. After the software update, a self-test should be performed manually to ensure the device is working correctly. Notes: •...
Z-Wave range tester signalling modes: Visual indicator pulsing green - Smoke-Control attempts to establish a direct communication with the main controller. If a direct communica- tion attempt fails, sensor will try to establish a routed communication, through other modules, which will be signaled by visual indicator pulsing yellow.
Page 9
Parameter: 4. Sound notifications status Description: This parameter allows to activate sound signals but does not apply to major alarms, such as Fire, Trouble and Low battery alarm. Available settings: 0 - all notifications disabled 1 - casing opening notification enabled 2 - exceeding temperature threshold notification enabled 4 - lack of Z-Wave range notification Parameter values may be combined, e.g.
Page 10
Parameter: 20. Temperature report interval Description: Time interval between consecutive temperature reports. Report is sent when new temperature value is different from the one previously reported - according to the set hysteresis (parameter 21). Temperature reports can be also sent as a result of polling. Available settings: 0 –...
The product Smoke-Control is produced by Nice S.p.A. (TV). Warnings: - All technical specifications stated in this section refer to an ambient temperature of 20 °C (± 5 °C) - Nice S.p.A. reserves the right to apply modifications to the product at any time when deemed necessary, while maintaining the same functionalities and intended use.
Page 12