1

WARNINGS AND GENERAL PRECAUTIONS

• CAUTION! – This manual contains important instructions and warnings for personal safety. Carefully read all parts of this manual. If
in doubt, suspend installation immediately and contact Nice Technical Assistance.
• CAUTION! – Important instructions: keep this manual in a safe place to enable future product maintenance and disposal pro-
cedures.
• CAUTION! – Any use other than that specified herein or in environmental conditions other than those stated in this manual is
to be considered improper and is strictly forbidden!
• The product's packaging materials must be disposed of in full compliance with local regulations.
• Never apply modifications to any part of the device. Operations other than those specified may only cause malfunctions. The manufacturer
declines all liability for damage caused by makeshift modifications to the product.
• Do not expose this product to moisture, water or other liquids.
• This product is designed for indoor use only. Do not use outside!
• This product is not a toy. Keep away from children and animals!
• If the battery is leaking and the contained material is ingested, rinse mouth and surrounding area with clear water. Seek medical attention
right away.
• Work within local code height requirements during installation of Smoke-Control. Take special precautions during installation and use tools
and equipment in perfect working order. It's recommended to observe ladders, lifts and other obstacles.
• Maintenance inspections should be performed regularly. Manufacturer recommends the functional and visual checks to be performed at
least once a week. Functional check includes self-test.
• When handled carelessly or used in non-specified environment conditions, the device may not function properly. It's highly recommended to
take all safety precautions to ensure safety and property protection.
• Current studies show that fire alarms may not awake all sleeping individuals and that it is the responsibility of other residents to assist those
who may not be awakened by the alarm sound or those who may be incapable of safely leaving the area unassisted.
CAUTION!
Depending on the Smoke Sensors' internal conditions (e.g. battery discharge, device failure, etc.) and ambient conditions, fire alarms are not
always effective in all situations. Smoke Sensors must be tested regularly according to this operating manual and local code. Ventilation sys-
tems, chimneys, and potentially dangerous devices that can cause a fire should be regularly inspected as well.
There are various situations against which the fire alarm may not be effective, for example:
1. Fires where the victim is intimate with a flaming initiated fire; for example, when a person's clothes catch fire while cooking;
2. Fires where the smoke is prevented from reaching the detector due to a closed door or other obstruction;
3. Incendiary fires where the fire grows so rapidly that an occupant's egress is blocked even with properly located detectors.
2

PRODUCT DESCRIPTION

Smoke-Control is a universal, optical Z-Wave™ smoke detector. A fire alarm is signaled by sound, visual indicator blinking, and sending Z-
Wave alarm and control commands.
The optical sensor detects smoke at an early stage of fire, often before flames appear and the temperature rises significantly. Moreover, the
device has a built-in temperature sensor, a programmable indicator of exceeding the set temperature level.
Smoke-Control is designed to be placed on a wall or ceiling. Visual indicator signals fire operating mode and are used to see if the device is
within the Z-Wave network. Smoke-Control is designed to operate in confined spaces under normal conditions (lacking smoke, dust, con-
densed water vapor).

Main features

Compatible with any Z-Wave™ or Z-Wave Plus™ Controller
Supports protected mode (Z-Wave network security mode) with AES-128 encryption
Extremely easy installation - simply install it in location prone to fire.
Battery powered
3 levels of sensors sensitivity
Built-in casing opening detector
Alarm is signaled by sound, visual indicator and Z-Wave control command
Programmable excess temperature warning
Automatic test performed every 10 seconds
Smoke-Control is a fully compatible Z-Wave Plus™ device.
This device may be used with all devices certified with the Z-Wave Plus certificate and should be compatible with such devices
produced by other manufacturers. All non-battery operated devices within the network will act as repeaters to increase reliability
of the network. The device is a Security Enabled Z-Wave Plus product and a Security Enabled Z-Wave Controller must be used
in order to fully utilize the product.