RHT60
Precision Psychrometer

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RHT60 and is the answer not in the manual?

Questions and answers

Summary of Contents for Triplett RHT60

  • Page 1 5 Commonwealth Ave 5 Commonwealth Ave Woburn, MA 01801 Woburn, MA 01801 Phone 781-665-1400 Phone 781-665-1400 User Manual Toll Toll Free 1-800-517-8431 Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com RHT60 Precision Psychrometer...
  • Page 2 Introduction Congratulations on your purchase of the Triplett Model RHT60 Hygro- Thermometer with Wet Bulb and Dew Point.. This device measures Humidity, Air Temperature, Dew Point temperature and Wet Bulb temperature. Advanced features include Data Hold, Auto Power Off, and...
  • Page 3 Operation Power Press the power button( ) to turn power on or off Taking measurements 1. Hold the probe in the area to be tested. 2. Allow adequate time for readings to stabilize. 3. The Relative Humidity measurement appears in the top display. 4.
  • Page 4 Wet Bulb Measurements 1. To select the Dew Point measurement, press the °F/°C/WBT/Dew Point button until WETBULB (°F or °C) appears in the lower right. 2. Wet Bulb temperature is now displayed. Temperature measurements To select the temperature measurement, press the °F/°C/WBT/Dew Point button until °C or °F appears in the lower right.
  • Page 5 Minimum (MIN) Maximum (MAX) Function The MIN/MAX mode allows the user to view only (MIN) (MAX) the lowest or highest readings. “MAX” MAX/MIN Press the button once and appears on the display. The LCD is now displaying the maximum humidity in the top display and the maximum reading of the selected parameter in the bottom display.
  • Page 6 while powering on. The symbol will not appear when auto power off has been disabled. The meter will revert to the default auto-off mode when powered off. Maintenance Cleaning and storage o The meter should be cleaned with a damp cloth and mild detergent when necessary.
  • Page 7 Specifications Function Range and Resolution Accuracy Humidity 0.0 to 10.0%RH ±3%RH 10.0 to 90.0%RH ±2%RH 90.0 to 100.0%RH ±3%RH Temperature -30.0 to -20.0 -22.0 to – 4.0 +/-0.9°F (+/-0.5°C) (at -19.9 to 70.0 25°C) -3.9 to 158.0 +/-1.5°F (+/-0.8°C) at all 70.1 to 100.0 other ranges 158.1 to 199.0...
  • Page 8 Triplett / Jewell Instruments extends the following warranty to the original purchaser of these goods for use. Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of (1) one year from the date of purchase.