Figure 10. Displacing The Sealing Strip And Releasing The Cables - Nokia MetroSite Maintenance Manual

Edge base station
Hide thumbs Also See for MetroSite:
Table of Contents

Advertisement

2.
3.
4.
Note
All connecting cables must be removed in order to remove the fan mounting
assembly.
5.
6.
7.
8.
Sealing strip
A
Allen screws
M6
Allen key 4 mm
Figure 10.
DN9913495
© Nokia Corporation
Issue 3-0 en
Nokia Proprietary and Confidential
All manuals and user guides at all-guides.com
Unclip and slide the cable cover towards you.
Disengage and remove the cable cover support plate.
Remove all connecting cables to the units. If necessary, make a note of the
cable connections before removing them.
Detach the outer sealing gasket at the point where it covers the cable entry
block, see (A) in Figure 10.
Remove the two 4 mm (0.157 in) Allen screws on the cable entry block.
See (B) in Figure 10.
Open the cable entry block at the point where the cables are routed.
Disengage the cables from the cable entry block.
Displacing the sealing strip and releasing the cables
Draft
Replacing units
41 (52)

Advertisement