Maytag 12591308 Owner's Manual page 24

Maytag side by side refrigerator owner's manual
Table of Contents

Advertisement

Before Calling Service
ICE & WATER
TOPIC
Ice maker is not producing
ice (some models-continued)
Unit is leaking water
Ice forms in inlet tube to
ice maker
Water flow is slower
than normal
Dispenser water is not cold
POSSIBLE CAUSE
Improper water valve was installed.
Plastic tubing was used to complete
water connection.
Improper water valve was installed.
Water pressure is low.
Freezer temperature is too high.
Water pressure is low.
Improper water valve was installed.
Water inlet tubing has kinks.
Water filter is clogged or needs to
be changed.
Refrigerator has been recently installed
Water supply in holding tank has
been depleted.
Water has settle into water lines outside
holding tank and has warmed to
room temperature.
SOLUTION
Check water connection procedure in your Installation
Instructions. Self-piercing and
low water pressure and may clog the line over time. The
manufacturer is not responsible for property damage
due to improper installation or water connection.
The manufacturer recommends using copper tubing
for installation. Plastic is less durable and can cause
leakage. The manufacturer is not responsible for
property damage due to improper installation or
water connection.
Check water connection procedure in your Installation
Instructions. Self-piercing and
low water pressure and may clog the line over time. The
manufacturer is not responsible for property damage
due to improper installation or water connection.
Water pressure must be between 20 to 100 pounds per
square inch to function properly. A minimum pressure of
35 pounds per square inch is recommended for units with
water filters.
See the controls section in your Owner's Manual for
assistance on how to adjust your controls. Freezer is
recommended to be between 0 to 2°F (-18 to –17°C).
Water pressure must be between 20 to 100 pounds per
square inch to function properly. A minimum pressure of
35 pounds per square inch is recommended for units with
water filters.
Check water connection procedure in your Installation
Instructions. Self-piercing and
low water pressure and may clog the line over time. The
manufacturer is not responsible for property damage
due to improper installation or water connection.
Turn off water supply and remove kinks. If kinks cannot be
removed, replace tubing.
Change water filter.
Allow approximately 12 hours for water in holding tank
to chill.
Discard first glass of water and refill.
24
3
/
" saddle valves cause
16
3
/
" saddle valves cause
16
3
/
" saddle valves cause
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents