2.

Power cord Arrangement

DANGER: Risk of electric shock. Disconnect power supply before servicing.
DANGER: Risk of electrical shock. For plug-in installations/wall-mounted electrical supply: connect only to
a properly-grounded, grounding-type receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI). Do
not remove the grounding pin or use a grounding adapter.
DANGER: Risk of electrical shock. Connect only to a properly-grounded, dedicated 220V~, 50Hz, 10A circuit
protected by a Class A Ground-Fault Circuit-Interrupter (GFCI) or Earth-leakage Circuit-Breaker (ELCB).
Note: no extended wire is allowed.
Note: receptacle without grounding wire is not allowed.
NOTE: This product is designed for installation with the electrical supply attached to the wall. Both types are
illustrated.
Refer to the dimensional information for your chosen installation.
1. Turn off main power supply before installation.
2. And ensure exposed power wire length no less than 600mm.
3. Plug power wire in backwards.
Kohler Co.
13
Wire in.
1357244-T01-E