About ON Mode
• All functions can be accessed when the remote control
LV LQ WKH 21 PRGH
‡ 2QO\ DFWLYH IXQFWLRQV ZLOO EH GLVSOD\HG ZKHQ WKH UHPRWH
FRQWURO LV LQ WKH 21 PRGH
Turning On the Heater
‡ 3UHVV WKH 32:(5 EXWWRQ WR WXUQ WKH KHDWHU 21 7KH
KHDWHU ZLOO ¿UVW LJQLWH WKH SLORW 2QFH WKH SLORW ÀDPH LV
HVWDEOLVKHG WKH PDLQ EXUQHU ZLOO EH OLW
NOTICE: Whenever the heater is cycled from OFF to ON,
the main burner will light on high for 10 seconds before
returning to the previous user setting.
Adjusting Flame Height
‡ 3UHVV WKH MENU EXWWRQ WR DFWLYDWH WKH PHQX
‡ 8VLQJ WKH UP and DOWN arrows highlight the FLAME
icon and press SELECT
‡ 8VH WKH UP and DOWN arrows to adjust the FLAME
HEIGHT, then press SELECT 7KH FLAME HEIGHT
FDQ EH DGMXVWHG WR  GL HUHQW VHWWLQJV
NOTICE: )/$0( +(,*+7 ZLOO QRW EH DGMXVWDEOH IRU ¿UVW
ten seconds when heater is turned on.
NOTICE: The system will remember the previous FLAME
HEIGHT setting and will automatically adjust after 10
seconds.
NOTICE: 6RPH PRGHOV XVH ¿[HG YDOYHV ZKLFK FDQQRW
be adjusted.
Adjusting Thermostat
‡ 3UHVV WKH MENU EXWWRQ WR DFWLYDWH WKH PHQX
‡ 8VLQJ WKH UP and DOWN arrows highlight the THERMO
icon and press SELECT
‡ 8VH WKH UP and DOWN arrows to turn the THERMO ON
or OFF, then press SELECT (the SET TEMP will start
EOLQNLQJ  8VLQJ WKH UP and DOWN arrows select the
desired temperature and press SELECT
NOTICE: If the THERMO function is on, the SET TEMP
can be adjusted at any time by pressing the UP and DOWN
arrows.
NOTICE: As the ROOM TEMP (RT) approaches SET
TEMP (ST), the remote system will automatically adjust
WKH ÀDPH KHLJKW ,I WKH 57 ULVHV DERYH 67 WKH KHDWHU ZLOO
shut down the main burner. After this, the heater will turn
back on after the RT drops below the ST.
NOTICE: The system requires a two degree Fahrenheit
RU KLJKHU WHPSHUDWXUH GL HUHQFH EHWZHHQ 57 DQG 67 IRU
the heater to turn on.
NOTICE: The system will remember the previous TEM-
PERATURE setting when THERMOSTAT mode is cycled
ON or OFF.
18
Monessen • AVFL Series Owner's Manual • 4099-900 Rev. D • 01/22
NOTICE: If your installation includes an optional wired
ON/OFF wall switch, it should be in the OFF position when
using the RC300 in thermostat mode.
Adjusting Timer
‡ 3UHVV WKH MENU EXWWRQ WR DFWLYDWH WKH PHQX
‡ 8VLQJ WKH UP and DOWN arrows highlight the TIMER
icon and press SELECT
‡ 8VH WKH UP and DOWN arrows to turn the TIMER ON
or OFF, then press SELECT 8VLQJ WKH UP and DOWN
arrows select the desired set time and press SELECT
7LPHU RSHUDWHV LQ LQFUHPHQWV RI      
DQG  PLQXWHV
Setting the Child Lock
‡ 3UHVV DQG KROG WKH MENU and UP arrow buttons simul-
taneously for 4 seconds to enable or disable the child
ORFN IHDWXUH
NOTICE: No functions will be usable until child lock feature
is disabled.
0DQXDO $SSOLDQFH 6KXWR
,Q WKH XQOLNHO\ HYHQW WKDW WKH UHPRWH ZDOO VZLWFK PDOIXQF-
WLRQV DQG ZLOO QRW WXUQ R WKH KHDWHU FDOO \RXU GHDOHU IRU
VHUYLFH DVVLVWDQFH ,Q WKH PHDQWLPH \RX PD\ FKRRVH
RQH RI WKH IROORZLQJ DFWLRQV WR WXUQ R WKH KHDWHU
CAUTION! Risk of burns! Heater surfaces are hot when
RSHUDWLQJ DQG GXULQJ FRRO GRZQ 8VH FDUH DQG ZHDU
gloves when opening the front and accessing compo-
QHQWV LQVLGH WKH KHDWHU
&KHFN UHPRWH VFUHHQ IRU EDWWHU\ OHYHO LQGLFDWRU UHSODFH
WKH EDWWHULHV LI ORZ EDWWHU\ LV LQGLFDWHG 6HH )LJXUH  
The appliance may be manually shut down by one of the
IROORZLQJ PHWKRGV
Disconnect power to the control module:
‡ 8QSOXJ WKH FRQWURO PRGXOH DQGRU UHPRYH EDWWHULHV
6KXW R JDV WR WKH FRQWURO
• /RFDWH WKH JDV VKXWR YDOYH WR WKH OHIW RI WKH JDV FRQWURO
‡ 5RWDWH WKH YDOYH  GHJUHHV WR WXUQ R JDV VXSSO\
• 7R SUHVHUYH EDWWHU\ OLIH GR QRW XVH WKH +,/2 ÀDPH
or THERMOSTAT options.
1RWH /(' OLJKWV RQ WKLV DSSOLDQFH DUH QRW FRQWUROOHG E\
WKH UHPRWH 7KH OLJKWV DUH FRQWUROOHG E\  EXWWRQV VHH
SDJH  