CS2674AX Withstanding Voltage lnstrument Huazheng Electric Manufacturing (Baoding) Co., Ltd...
Page 2
(0312) 6775656 to tell you to serve you at all times- Baoding Huazheng Elect ric Manufact ur ing Co. , Lt d. , our company will def initely make you satisf ied !
I.Unpacking and installation tester 1.Check the received instrument When you receive Allwin’s equipment, check the tester follow the below steps: (1)The instrument box is intact; if damaged, we recommend that you do not unpack the box, but contact with the company's distributors or Allwin Instrument Company. (2)If the instrument package is good, then please check what you have ordered instrument model are the same with the model label on the box;...
Page 5
Instrument storage temperature range: -20 º C ~ +70 º C; (3)Do not use the tester in humidity environment Do not put the instrument on a boiler, kettle, humidifier water or moist environments. Condensation of water droplets may lead to Internal short-circuit and damage the instrument, even if it can cause serious fires.
Page 6
the voltage, current and resistance; Operator must know during the high-voltage test, high voltage is generated form high voltage output port, after flowing from device under test(DUT), by the end of RETURN cable into the tester inner; If you touch any of the items, it will be caused high-voltage electric shock.
Replace the fuse, follow these steps: (1) Turn off the power switch and unplug the power cord; (2) Fixed with a screwdriver to open the fuse holder as shown below; (3) Check and replace the fuse, it must be the same with specifications listed in the 1.7.1; (4) The fixed fuse holder should be back in its original location.
Page 8
power switch repeat and frequently. When the tester outputs high-voltage, don’t turn off the power switch, except in urgent cases can perform this operation. (2)High-voltage output and ground could not be short-circuit. The high-voltage test leads of the tester are strictly prohibited to be short-circuit with the AC power cord or other electrical equipment connected to the ground.
Page 9
3.3 Connect the test leads to high voltage output After connected the test line of current measurement, then connect high-voltage output line obey the following procedure: (1) Press [STOP] key. (2) To confirm the test light does not light. High-voltage output cable plugs into the high voltage output port. 3.4 Replace DUT (4) When one test is completed, the replacement of another DUT, please confirm: (5) (1) Tester is in the "reset"...
CS2674AX hipot tester is without over zero start function, in the moment of start button pressed, high voltage output may from the sine wave peak or trough of the sine wave; which may generate high voltage overshoot. Also, if turn off the power switch, high voltage overshoot also may be caused.
Page 11
6、 AC high voltage output ports; 7、 testing grounding ports; 8、 DC high voltage output ports; 9、 Power supply safety detecting indicator light “O K” 10、 High voltage output indication 11、 Over run light: When light is on, it indicates the tested devices overrun is disqualified. 12、...
1. Input power supply socket Three core two-phase power socket. There is fuse in the power socket. 2.Protective earth The protected earth terminal needs to be reliably connected to the protective ground. Otherwise, the case of the tester may be filled with high-voltage and cause the electrical shock.
Page 13
The hipot tester comes with power safety detection function, there is an "OK" indicator lamp on the front panel, if the "OK" indicator both lights, power input is correct, you can press the start button, if either “o” or “k” not bright, the input power is error, please do not start the hipot tester and check the input power supply.
V.Specifications This chapter introduces the technical parameters of various testers in detail. 5.1 Technical parameters Model CS2674AX Output voltage (0.00~20.00)kV range Maximum output 200VA power Maximum rated 10mA current Current gear 2mA、10mA Output waveform Sine wave Output waveform ≤5% distortion 0.0s~999s 0.0=continuous test...
VI.PLC interface There is remote control connection terminal on the back plate of the tester. This terminal can connect to remote manipulator to operate. It is a standard 9PIN D type terminal, with the following signals: connection test signals, reset signal, signal under testing, test pass signal, test fail signal.
4.Electrical Performance of Interface Output contact voltage: 24 V AC/DC Max. Current: 100mA Terminal voltage when the input terminal connects to non-voltage control contact and has null connection: <10 V DC VII.Operation Instructions and Procedures 1. Pre-set the test time 2.
potentiometer clockwise, the current pre-set value will be increased. Counterclockwise adjustment will reduce the pre-set leak current. If the preset current is up to the desired value, pop-up the test / preset button. 3.Adjust the output voltage When the voltage regulator knob is at 0 position, even if user starts the tester from PLC, there is no high voltage output.
knob at a desired value, the tester will do the test continuously. During the test, if the test current is great than the preset value, the tester will alarm with sound and light. Set the “RESET”signal enable, the alarm will be stopped. Replace the DUT and continue to test. After testing, enable the “RESET”...
(2)Connected with the tester's alligator clip test leads; (3)Products being tested (DUT); (4)Any object connected to the tester; 9.2To prevent electric shock accidents, please follow the following safety steps: (1)To prevent electric shock accidents in the use of tester, user had better wear insulated rubber gloves and then engage in operation to the tester.
Need help?
Do you have a question about the CS2674AX and is the answer not in the manual?
Questions and answers