Nemalux LS Series Manual

Temporary lighting string

Advertisement

Nemalux
I N D U S T R I A L
TEMPORARY LIGHTING STRING

APPLICATION

Intended for temporary lighting requirements in industrial, marine and hazardous locations, the LS
light stringer is rated for indoor and outdoor use. With a protection level of IP66 / NEMA4X the
versatile LS o ers a lightweight solution for surface and hook mount applications during construc-
tion, operation and maintenance.
Conforms to:
Hazardous Location Certi cation:
Housing:
Rated Voltage:
Rated Power:
Connections:
Temperature Range:
Ingress Protection:
MADE IN CANADA
TM
Installation
UL 844, UL 1088, CAN/ULC-S1088, UL 1598, UL 1598A:
CSA 22.2 No. 137
Class I, Division 2, Groups ABCD, T5;
Class II, Division 1, Groups EFG, T5;
Class III;
Class I, Zone 2, Groups IIC;
Class I, Zone 20, Groups IIIC
Copper-free Case Aluminum & Borosilicate Glass
120 VAC , 50/60 Hz
19.5W per module
Standard: Black: Line | White: Neutral | Green: Ground
-50° C to +70° C
IP66/67 | Suitable for Wet Locations. Marine Outside type (Salt water).
www.nemalux.com | sales@nemalux.com | Tel 403•242•7475 | Fax 403•243•6190
Spec Sheet
Webpage
LS Series
rev. A-20
1-6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LS Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Nemalux LS Series

  • Page 1 Standard: Black: Line | White: Neutral | Green: Ground Temperature Range: -50° C to +70° C Ingress Protection: IP66/67 | Suitable for Wet Locations. Marine Outside type (Salt water). www.nemalux.com | sales@nemalux.com | Tel 403•242•7475 | Fax 403•243•6190 MADE IN CANADA...
  • Page 2 If the temporary lighting string will be installed in a wet location, the junction box or connector used must be Listed/Recognized for use in Wet Locations. STEP 1: Inspect shipping package and contents to ensure no damage has occurred during shipping. www.nemalux.com | sales@nemalux.com | Tel 403•242•7475 | Fax 403•243•6190 MADE IN CANADA...
  • Page 3 NOTE: For replacement of damaged Cord, refer to Assembly of LS-KIT into Approved Temporary String Light instruc tions on page 3-4. STEP 5: Plug-in or energize circuit. www.nemalux.com | sales@nemalux.com | Tel 403•242•7475 | Fax 403•243•6190 MADE IN CANADA...
  • Page 4 (hazardous) zone, connector must be rated for the hazardous Class and Division/Zone where the connection is made. STEP 1: Inspect shipping package and contents to ensure no damage has occurred during shipping. www.nemalux.com | sales@nemalux.com | Tel 403•242•7475 | Fax 403•243•6190 MADE IN CANADA...
  • Page 5 Attach End Cap Assembly to the core with the supplied M4 socket head cap screws (3) with M4 hex driver torque to 2.3 N-m (20 in-lbs). STEP 5: Repeat steps 2-4 for other side of module. www.nemalux.com | sales@nemalux.com | Tel 403•242•7475 | Fax 403•243•6190 MADE IN CANADA...
  • Page 6 (handrail, exposed beams, pipe rack, etc.) in desired location with adjustable strapping, hook, or surface mount bracket accessories. Cam buckle straps, stainless steel mounting clamps, hook and surface mounts are available separately. www.nemalux.com | sales@nemalux.com | Tel 403•242•7475 | Fax 403•243•6190 MADE IN CANADA...

Table of Contents