Local Console Manager LCM8 and LCM16 Installation and User's Guide
To install the switch horizontally in the 1U rack mounting space:

Figure 2.3: Horizontal rack mount assembly

NOTE: If you install the switch horizontally in the 1U rack mounting space, you must install the filler panel in the
front of the rack to prevent recirculation of hot air from the rear of the rack to the front.
1.
Remove the screws from each side of the switch.
2.
Line up the small holes in the long side of each mounting bracket.
3.
With a Phillips screwdriver, fasten the mounting brackets to the switch using two #8 32 x 5/16-
inch pan-head screws on each side.
4.
Attach four cage nuts or clip nuts to the rack mounting flange of the rack so that each nut is
positioned on the inside of the rack.
5.
Mount the switch assembly to the rack by matching the holes in the short side of each
mounting bracket to a set of matching holes on the rack. Insert the combination hex-head
screws through the slots in the mounting bracket and the holes in the mounting rail, and then
into the four cage nuts or clip nuts.

Connecting the LCM8/LCM16 switch hardware

To connect and turn on your LCM8/LCM16 switch:
NOTE: You must turn off all target devices that will be part of your LCM8/LCM16 switching system. Wait until
step 6 to turn on your LCM8/LCM16 switch.
1.
Connect your
cables into the appropriately labeled ports on the LCM8/LCM16 switch.
2.
Connect a compatible CO cable into the appropriate ports on the back of the target device.
VGA, SVGA, SGA, or SXGA
monitor, and either PS2 or USB keyboard and mouse