2. Maintenance

2-1. Maintenance Schedule

No.
Part Name
1
Zoom Motor Unit
The maintenance execution time shown in the above is recommendation for standard maintenance execution.
This is not life of various parts. The life is influenced by temperature, humidity, dust, etc..

2-2. Confirmation method of operation number of times

The operation number of times of Zoom Motor is displayed on item SERVO ZOOM in DIAGNOSTICS menu
screen.
1. Push the button in order of "RESET/TC SET" button → "STOP" button → "DISP/MODE CHK" button →
"MENU" button.
NOTE: "STOP" button = Push the OPERATION lever in the ▼ direction.
2. Push the OPERATION lever in the ▲ or ▼ direction to select the DIAGNOSTICS menu. And push the
SET(STILL) button to open the DIAGNOSTICS menu.
3. Push the OPERATION lever in the ▲ or ▼ direction to display the item "SERVO ZOOM".
DIAGNOSTICS
ERROR RESET
SERVO ZOOM
SHUTTLE SPEED
UPDATE
SETUP
ENTER
The operation number of times can be confirmed also with the PC EVR software. Please refer to < Display of
operation number of times > of item "5-4-5. Display of ZOOM MOTOR operation number of times" about
display procedure by PC EVR software (page INF-20).

2-3. Reset of operation number of times

After replacing Zoom Motor unit, set the operation number of times to 0 times.
Please refer to < Setting of operation number of times > of item "5-4-5. Display of ZOOM MOTOR operation
number of times" about setting procedure by PC EVR software (page INF-20).

2-4. Replacement procedure of Zoom Motor unit

The removal procedure has been described to the item "12. Removal of Zoom Motor Ass'y" of disassembly
procedure (SECTION 2).
Part No.
L6DABBKC0001
2/2
NO
000200T
x4
NO
EXIT
MENU
INF-3
Pcs
1
Every 100,000 number of times (SERVO ZOOM)
* Please refer to the following procedures.
The operation number of times of the zoom
motor of the lens unit is displayed.
NOTE: The operation number of times is
displayed by every 100 number of
times.
Replacement