Panasonic AG-HMC150P/AN Service Information page 16

Table of Contents

Advertisement

2. Unscrew the 3 screws (A) as shown in figure and remove the REAR SIDE COVER.
SCREW (A)
REAR SIDE COVER
3. Connect the Extension Cable (VFK1989) to connector P2 on Measuring Board (VFK1988).
Connect VFK1989 with connector P2
as shown in picture.
The unit will not work if the
connector is attached backwards.
4. Connect the Extension Cable (VFK1989) to EVR connector in Unit. Then make sure that the direction of the
VFK1989 is correct as shown in Figure.
When the VFK1989 is connected to EVR connector, be careful of the direction of connector on VFK1989.
Please follow as shown in the figure.
EVR CONNECTOR
VFK1989
P2
VFK1989
INF-14
SCREW (A)