8. Factory Initialize

Please note that the following data etc. are initialized when the FACTORY initialization is executed.
Value of current operating status of setting menu (included scene file F1 to F6) → factory default
Value of user file in EEPROM → factory default
Counter display → Time code display
Value of TCG/UBG and COUNTER → 0
CAMERA micon → factory default
XP micon → factory default
NOTE: The value of the hour meter is not reset (OPERATION TIME & SERVO ZOOM).
< Initialize procedure >
1. Confirm that the SD card does not insert in slot of camera recorder.
2. This camera recorder is set to CAM mode.
3. The following three buttons are pushed at the same time for two seconds or more.
[ EXEC ] + [ REW ] + [ REC START/STOP ]
REW (Tilt the operation lever in the ◄ direction)
4. It is blink displayed as "FACTORY INIT" on the LCD panel.
5. After initialization is completed, it replaces the "FACTORY INIT OK: * " display.
The mark * is indicated as shipment destination information. Please confirm that mark is corresponding to the
destination of the camera recorder.
Ex.) In case of AG-HMC150P, it displayed as "P".
FACTORY INIT
6. Turn power off the camera recorder.
NOTE: Factory initialize can be executed by PC EVR software (VVS0069). Please refer to item "6-3-4. Factory
Initialize" (page INF-27).
EXEC button
INF-39
REC START/STOP button
FACTORY INIT OK: *
TURN POWER OFF