With all the fixings screws and the motors disconnected remove the motor plate
from the hood and reverse the position of the motor(s). See Fig 4
Duct Installation
Make a hole or holes in the walls and/or ceiling, as necessary, in order to take
150mm diameter ducting from the extractor spigot(s) to the outside.
The exhaust duct route length should be kept as short as possible with as few
bends as possible.
If using FdF duct kit ensure that holes in external wall will accommodate the
ducting and connecting strap (Min 160mm diameter).
Warning
Do not reduce the ducting diameter from 150mm as this will affect the
performance of the hood and could damage the motor. Damage caused
to the hood by incorrect ducting will not be covered by warranty.
Fig 4