Download Print this page

Alto MC700.4 Service Manual page 5

Hide thumbs Also See for MC700.4:

Advertisement

1
P1
D
PC250-90
P2
TRANS-IN
PC250-90
P3
PC250-90
P4
C
PC250-90
P5
PC250-90
P6
NEUTRAL
PC250-90
B
115V/25A
BREAKER
230V/18A
1
1
2
2
P10
1
2
NEUT
P11
A
1
2
PC187
1
2
1
115V or 120V
2
1
2
0V
T130 ℃
1
2
115V or 120V
1
2
1
2
0V
T130 ℃
1
2
PT-MIS6000-E
POWER SWITCH
P7
CN-PCB6.3
P9
1
2
LINE
P15
CN-PCB6.3
P12
1
2
1. COMPONENTS WITH
CN-PCB6.3
2
100V
0V
100V
100V
0V
100V
13.5V
TRANS-IN
0V
P8
CN-PCB6.3
SWITCH
P16
NEUTRAL
CN-PCB6.3
ARE SAFETY CRITICAL PARTS.
03-1
3
BD1
35A/200V
BRIDGE1+
BRIDGE1-
COM1
BD2
35A/200V
BRIDGE2+
BRIDGE2-
COM2
AC_1 (AC_2)
COM
R2_68
NTC NP35L
R2_67
NTC NP35L
D2_31
R2_73
R2_74
2K7 10W
2K7 10W
1N4004
MIS60PWR
Titel
Size
Model No:
MISTRAL6000
A4
6-Mar-2006
Date:
File:
MIS60PWR.Sch
3
4
D
C
K2_2
4
5
3
B
1
2
832A-1A-C
C2_46
470uF/50V
A
Revision
VER050201
Sheet
Drawn By:
4

Advertisement