Download Print this page

Operating Logics - Genius BRAIN 16 Quick Manual

Advertisement

2
OPENING LEAF DELAY M2 WITH
RESPECT TO M1
BRAIN 16
BRAIN 16
ON
ON
1
2
3
1
2
3

4. OPERATING LOGICS

Description of the E logic: With the automated system stationary - An OPEN pulse opens the
TOP
FSWCL
FSWOP
DL5
DL4
Description of the EP logic: With the automated system stationary - An OPEN pulse opens the
Description of the B logic: With the automated system stationary - Logic with two separate
Description of the C logic: With the automated system stationary - logic with two separate
-
14
11
12
13
OP
CL
B
STOP
FSW
Description of the A logic: With the automated system stationary - an OPEN pulse opens the
Description of the AP logic:With the automated system stationary - an OPEN pulse opens the
732789_Quick_Rev.A
2 seconds
0
DS1
ON
OFF
4
5
6
7
8
9
10
11
4
5
6
7
8
9
10
11
FAIL SAFE
Yes
No
gate and the following one will close it.
With the automated system moving - An OPEN pulse while opening
locks and reopens during closing.
Photocell engagement - During motion, the photocells reverse
gate and the following one will close it.
With the automated system moving - An OPEN pulse during motion
locks.
Photocell engagement - During motion, the photocells reverse
commands: OPEN-A pulse opens; OPEN-B pulse closes
With the automated system moving - An OPEN-A pulse during closing
opens..
Photocell engagement - During motion, the photocells reverse
commands: OPEN-A maintained opens; OPEN-B maintained closes
15
16
17
18
With the automated system moving - An OPEN-A command during
TX
LOCK
+24V
FSW
closing opens, an OPEN-B command during opening stop.
Photocell engagement - During motion, the photocells reverse
gate and, when the pause time elapses, closes it automatically.
With the automated system moving - An OPEN pulse during opening
is ignored, during the pause it resets and during closing it reopens.
Photocell engagement - The closing photocells reset the pause.
During motion, the photocells reverse
gate and, when the pause time elapses, closes it automatically.
With the automated system moving - An OPEN pulse during the pause
locks, during opening it locks and during closing it reverses.
Photocell engagement - The closing photocells reset the pause.
During motion, the photocells reverse
CLOSING PHOTOCELLS
DL8
SW1
ON
F
OFF
DS2
ON
ON
12
1
ON
4
12
1
2
3
4
12
1
2
3
4
SW3
OVER-PUSHING STROKE
ON
CH1
OFF
DL6
SW2
-
19
4
LOGIC
Reverses on release
Reverses immediately
SW1
DS2
REVERSE STROKE +
Yes
No
SW2
ON
OFF
SW4
ON
OFF
Brain 16

Advertisement

loading