IMPORTANT: READ AND UNDERSTAND THIS OPERATIONAL MANUAL BEFORE
en
PERFORMING ASSEMBLY, COMMISSIONING OR MAINTENANCE ON THIS HEATER.
it
INCORRECT USE OF THE HEATER CAN CAUSES SERIOUS INJURY. KEEP THIS
de
es
(WARNINGS)
fr
IMPORTANT NOTICE: This device
!
nl
is not suitable for operation by persons
(including children) with impaired physi-
pt
cal, sensory or mental faculties, as well
as inexperienced personnel, unless su-
da
pervised by a safety guardian. Children
fi
are not to be left unattended as to ensure
they are not playing with the equipment.
no
WARNING:
sv
!
poisoning can prove to be fatal.
pl
First symptoms of carbon monoxide poisoning
are similar to influenza with severe headaches,
ru
dizziness and/or nausea. Such symptoms may
cs
be caused by heater fault. UPON NOTICING
THESE SYMPTOMS, IMMEDIATELY LEAVE
hu
THE ROOM AND GO OUTSIDE, next, notify
the technical service center that the heater
sl
needs to be repaired.
tr
1.1. SUPPLY:
►1.1.1. Personnel in charge of supply must
hr
be fully qualified, must be familiar with the
lt
manufacturer's manual as well as the effective
regulations for safe supply of heaters.
lv
►1.1.2. Only the fuel types specifically listed
on the heater's nameplate are to be used.
et
►1.1.3. Before refueling, shut down the heater
ro
and wait for it to cool down.
►1.1.4. Fuel cisterns are to be located in a
sk
separate facility.
►1.1.5. All fuel containers are to be located
bg
within safe distance from the heater, as per
uk
the applicable regulations.
►1.1.6. Fuel is to be stored in rooms with
bs
insulated floor, so that the fuel cannot
penetrate the floor into the open flame below
el
causing fuel combustion.
►1.1.7. Fuel storage needs to follow all the
zh
applicable regulations.

1.2. SAFETY CONSIDERATIONS:

►1.2.1. The heater should never be used in
rooms with fuel, paint thinners and other
combustible fumes.
►1.2.2.
All
applicable
regulations need be observed while using
the heater.
MANUAL FOR FURTHER REFERENCE.
Carbon
monoxide
local
rules
and
►1.2.3. Heaters in operation near tarpaulin,
screens or other similar materials need to
be located a safe distance away. The use of
inflammable covers is highly encouraged.
►1.2.4. The device is to be used in well
ventilated interiors only. To ensure proper air
circulation, a proper opening is required, as
per the applicable regulations.
►1.2.5. For heater power feed observe closely
the voltage and frequency values given on
the nameplate.
►1.2.6.
Only
use
extension cords.
►1.2.7. Minimal safety distance between the
heater and combustible materials is: front =
2,5 m (8 ft); side, up and back = 1,5 m (5 ft).
►1.2.8. To avoid fire, hot or working heater is
to be placed on a stable and leveled flooring.
►1.2.9. Animals are to be kept at a safe
distance away from the heater.
►1.2.10. Unplug the heater at all times during
downtime.
►1.2.11. Thermostat control allows the heater
to be turned on at any time.
►1.2.12. The heater must not be used in
frequently visited rooms and in bedrooms.
►1.2.13. Do not obstruct the airflow (back of
the device) and air intake (front) of the heater.
►1.2.14. If the heater is plugged in, hot,
or currently running, it must not be
moved, manipulated, refueled or attempt
maintenance work of any kind.
►1.2.15. Do not channel the air flow at intake
or the heater output.
►1.2.16. Keep the safe distance between the
hot parts of the heater and thermosensitive
or combustible materials (including feeder
cable).
►1.2.17. In case the feeder cable is damaged,
have it replaced at the technical service
center to avoid danger.
►2.1. Remove all the heater wrapping and
packaging materials then dispose of them as
per the applicable local regulations.
►2.2. Remove all the components from the
box.