PROGRAMMING MANUAL FOR AM45 MOTORS ER-P SERIES
1. TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
Limit swiches:
Operating temperature:
Protection degree:
Frequency:
Average range:
Reacts on the obstacles.
Works with all AC series transmitters included in the ALUPROF S.A. offer.
Ability of programming up to 20 transmitters. Each next transmitter will overwrite the last programmed one.
Company reserves the tolerance of catalog data due the different conditions usage.
2. ELECTRICAL CONNECTIONS
- Installation of the motor should be carried out by authorized persons.
- The motor is designed for use in dry rooms and should not be exposed
to direct weather conditions.
- The motor should be powered by a separate circuit and protected by a
quick fuse for example: circuit breaker type B10
We reserve the right to any technical change.
Valid on 2022.01.27
PROGRAMMING MANUAL FOR AM45 MOTORS ER-P SERIES
230 VAC / 50 Hz
135 W, 170 W, 200 W
Electronic
~ -10°C - ~ +60°C
IP44
433.92 MHz
80 meters (in open space), 20 meters (inside buildings)
230V / 50Hz
NOTE
For the obstacle response system to work properly:
- security springs WB or WL&P, W OCTOEASY must be used,
- side locks or stoppers in the endslat must be used,,
- adjust the maxiumum torque of the motor (Nm) to the weight of the
curtain,,
- upper and lower limit position sholud be set up
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the ER-P Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Aluprof ER-P Series

  • Page 1 80 meters (in open space), 20 meters (inside buildings) Reacts on the obstacles. Works with all AC series transmitters included in the ALUPROF S.A. offer. Ability of programming up to 20 transmitters. Each next transmitter will overwrite the last programmed one.
  • Page 2 PROGRAMMING MANUAL FOR AM45 MOTORS ER-P SERIES 3. REMOTE CONTROLLERS AC134-06 AC133-05 STOP DOWN AC134-02 AC133-02 AC134-01 AC133-01 AC116-04 AC129-04 AC129-01 AC136-01 AC136-06 AC136-16 STOP AC116-03 DOWN DOWN STOP AC127-01 AC127-06 AC127-16 AC140-16 AC140-06 AC140-01 STOP DOWN - activation of this button will move curtain up.
  • Page 3 PROGRAMMING MANUAL FOR AM45 MOTORS ER-P SERIES Is important to adjust the sensitivity of the overload mechanism to the size of the roller shutter. 4. SWITCH TO PROGRAMMING MODE Press and hold the The motor will make a short Programming mode activated.
  • Page 4 PROGRAMMING MANUAL FOR AM45 MOTORS ER-P SERIES 6. MANUAL SETTINGS OF LIMIT POSITIONS UPPER The motor will make a short Press the „UP” button and hold Press STOP when courtan reache On the transmitter press for 2 seconds. limit position, correct the position move DOWN - UP.
  • Page 5 PROGRAMMING MANUAL FOR AM45 MOTORS ER-P SERIES 7. AUTOMATIC SETTING OF LIMIT POSITIONS The motor will make a short Press the „STOP” and „UP”. After overload mechanism On the transmitter press Roller shutter opens. move DOWN - UP. is activated motor will change the „P2”...
  • Page 6 PROGRAMMING MANUAL FOR AM45 MOTORS ER-P SERIES 8. ERASING THE LIMIT POSITIONS The MOTOR can’t be in the limit positions during reset. Press the „P2” button and hold it After 1 second the motor will After 7 seconds the motor will The limit positions for 7 seconds.
  • Page 7 PROGRAMMING MANUAL FOR AM45 MOTORS ER-P SERIES 12. REDUCING THE SENSITIVITY OF THE OVERLOAD SYSTEM. Sensitivity range 1 (lowest) - 5 (highest). Default set to 3. Decreasing it changes by 1 level. Press the „UP” and „DOWN” buttons Press the „STOP” and „DOWN”...
  • Page 8 PROGRAMMING MANUAL FOR AM45 MOTORS ER-P SERIES 14. FACTORY SETTINGS RESTORING. Switch to programming mode Press the „P2” button and hold it The motor will make a short Factory settings restored. according to point 4. for 7 seconds. move DOWN - UP.

This manual is also suitable for:

Am45-20/17-er-pAm45-10/17-er-pAm45-40/12-er-p