Nstalling The Xterior Oods; Connecting The Drain - vanEE NOVO+ 100H Installer Manual

Hide thumbs Also See for NOVO+ 100H:
Table of Contents

Advertisement

4. INSTALLATION (
4.7 I
E
NSTALLING THE
XTERIOR
Choose an appropriate location for installing the exterior
hoods:
• At a minimum distance of 6 feet (1.8 m) between the
hoods to avoid cross-contamination
• At a minimum distance of 18 inches (457 mm) from the
ground
!
WARNING
Make sure the intake hood is at least 6 feet (1.8 m)
away from any of the following:
• Dryer exhaust, high efficiency furnace vent,
central vacuum vent
• Gas meter exhaust, gas barbecue-grill
• Any exhaust from a combustion source
• Garbage bin and any other source of contamination
Refer to illustration at right for connecting the insulated duct
to the hoods. An "Anti-Gust Intake Hood" should be installed
in regions where a lot of snow is expected to fall.
4.8 C
D
ONNECTING THE
RAIN
Cut 2 sections of the plastic tube, minimum 12" long, and attach them to each inner drain
fitting, located under the unit.
Join both short sections to the "T" junction and main tube as shown, to prevent the unit from
drawing unpleasant odors from the drain source.
Run the tube to the floor drain or to an alternative drain pipe or pail.
IMPORTANT
If using a pail to collect water, locate the tube end approximately 1" from the top of the pail in
order to prevent water from being drawn back up into the unit.
'
)
CONT
D
H
OODS
E
XHAUST
H
OOD
I
NTAKE
H
OOD
18"
(457
)
MM
6'
(1.8
)
M
T
APE AND DUCT TIE
C
AULKING
VD0028
10
6" ø
(152
)
MM
18"
(457
)
MM
O
PTIONAL
DUCT LOCATION
12" minimum
VD0325A
± 1"
VD0308A
6'
(1.8
)
M
18"
(457
)
MM
T
IE WRAP
12" minimum

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for vanEE NOVO+ 100H

This manual is also suitable for:

Novo+ 200h16017171601719

Table of Contents