Open Energy for All Single-phase Microinverter USER MANUAL HM-300 HM-350 HM-400 Region: Global V202203 hoymiles.com...
Page 2
PV module, consequently improving the flexibility and reliability of the system About the Manual This manual contains important instructions for the HM-300/HM-350/HM-400 Microinverter and must be read in its entirety before installing or commissioning the equipment. For safety purposes, only a qualified technician who has received training or has demonstrated competence may install and maintain this microinverter under the guidance of this document.
Do not use the equipment if any anomalies are discovered while operating. Avoid temporary repairs. • All repairs should be carried out by using only qualified spare parts, which must be installed in accordance with their intended use and by a licensed contractor or authorized Hoymiles service representative. •...
“Daisy-Chain Single Unit Microinverter” with wide DC input operating voltage range (16 V–60 V) and low start-up voltage (22 V only). The Hoymiles Single Unit Microinverter HM-300/HM-350/HM-400 is a reliable solution for PV systems with an uneven number of panels, and offers high CEC weighted efficiency – 96.50% (peak efficiency 96.70%) in 2015.
Single-phase Microinverter User Manual 6. Troubleshooting This microinverter can only work with the new Hoymiles DTU (DTU-Pro, DTU-Lite and DTU-W100/DTU-G100) with the following serial number. Model Serial Number 10F7xxxxxxxx DTU-Pro 10F8xxxxxxxx 10FAxxxxxxxx DTU-G100 10D2xxxxxxxx DTU-W100 10D3xxxxxxxx DTU-Lite 10D6xxxxxxxx Troubleshooting List...
(3) Other Status • Alternating red and green flashing: Firmware is corrupted. *Note: All faults are reported to the DTU, refer to the local DTU app or S-Miles Cloud (Hoymiles Monitoring Platform) for more information. Insulation Resistance Detection There is a resistance sensor in the microinverter to measure the resistance between the outputs of PV module and the ground.
Avoid temporary repairs. All repairs should be carried out by using only genuine spare parts. If all microinverters connect to the DTU-Pro, the DTU can limit the output power imbalance of all microinverters between phases to below 3.68 kW if required. Please refer to the “Hoymiles Technical Note Limit Phase Balance” for more details.
Storage and Transportation Hoymiles packages and protects individual components by using suitable means to facilitate the transport and subsequent handling. Transportation of the equipment, especially by road, must be carried out by using means that are suitable for protecting the components (in particular, the electronic components) from violence, shocks, humidity, vibration, etc.
DC short-circuit current. The output DC power of the PV module is NOT recommended to exceed 1.35 times the output AC power of the microinverter. Refer to the “Hoymiles Warranty Terms & Conditions” for more information.